Operating the Programmer
26
3.
Or place the AT5549 End-of-Train Tag reflective side up into programmer
adapter, slide into the tag holder (
), and close the door.
Figure 9 Programmer Adapter and AT5549 EOT Tag Being Slid into Tag Holder
If the tag is placed before or during the 10-second period, the programmer programs
the user data, verifies the user data, and sends a response to the host system. If the tag
is not placed during the 10-second period, the programmer aborts the command, sends
the #Error<cr> response to the host, and emits a continuous audible tone.
When the tag is successfully programmed, the programmer responds with a triple beep
and with the following response:
xxx...<cr>
#Done<cr>
where xxx... is the tag data read from the tag and is encoded in the specified format.
If the tag programming process fails, the programmer responds with a continuous
audible tone and with #Error<cr>.
If you receive this response, repeat this sequence beginning at step 1. Also refer to
for troubleshooting remedies.
Verifying Tag Data
To verify the data on a tag
1.
Send the programmer the appropriate command. Use command #210 if you are
using the TransCore 6-bit format for your data, command #211 for the 4-bit hex