7
2.3 Structure of SMS containing settings
The module can send current settings in SMS (see item 6/1. of the programming menu).
The settings are sent in 2 SMS messages, having the following structure:
Example:
GSM settings (1):
TEL1=06301111111/Y
(
TEL1…TEL4
= the 4 adjustable user phone numbers, after
TEL2=06302222222/Y
the phone numbers the confirmation setting can be found)
TEL3=06203333333/N
/Y
= event must be confirmed from this phone number
TEL4=06704444444/N /N
= event confirmation is not requested from this phone nr.)
M STAT=0615555555
(
M STAT
= monitoring station phone number)
GSM settings (2):
Z1=NO
(input 1 setting:
NO
= normally open)
Z2=NC
(input 2 setting:
NC
= normally closed)
RELTIME=0002
(relay active state duration in seconds)
USER ID=1234
(4 digit decimal user account ID)
EVENT_Z1=130
(Contact ID code of input 1 -
130
=burglary)
EVENT_Z2=130
(Contact ID code of input 2 -
130
=burglary)
EVENT_LOW V=302
(Contact ID code of low supply voltage)
EVENT_TEST=602
(Contact ID code of periodic test report)
TESTDAYS=7
(Automatic test report sending period in days)
LOW V REP=Y
(Supply voltage monitoring setting -
Low
v
oltage
rep
ort:
Y
=enabled,
N
=disabled)
CALLID CHK=N
(Caller identification:
Y
=enabled,
N
=disabled)
3 Module
overview