138 Parameters
Defines the minimum for the frequency actually arriving at
frequency input 1 (DIO1 when it is used as a frequency
input).
The incoming frequency signal (
) is scaled into an internal signal (
) by parameters
…
as follows:
0 Hz
0…16000 Hz
Minimum frequency of frequency input 1 (DIO1).
1 = 1 Hz
Defines the maximum for the frequency actually arriving at
frequency input 1 (DIO1 when it is used as a frequency
input). See parameter
16000 Hz
0…16000 Hz
Maximum frequency for frequency input 1 (DIO1).
1 = 1 Hz
Defines the value that is required to correspond internally
to the minimum input frequency defined by parameter
. See diagram at parameter
0.000
-32768.000
…32767.000
Value corresponding to minimum of frequency input 1.
1 = 1
Defines the value that is required to correspond internally
to the maximum input frequency defined by parameter
. See diagram at parameter
1500.000;
1800.000
(
b0)
-32768.000
…32767.000
Value corresponding to maximum of frequency input 1.
1 = 1
Displays the value of frequency output 1 after scaling. See
parameter
This parameter is read-only.
-
0…16000 Hz
Value of frequency output 1.
1 = 1
Selects a signal to be connected to frequency output 1.
Zero
None.
0
Motor speed used
(page
).
1
Output frequency
(page
3
Motor current
4
Motor torque
6
No.
Name/Value
Description
Def/
FbEq16
f
in
)
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...