Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
1 = 1 % / 10000 = 1 %
Voltage boost at zero speed in percent of nominal
motor voltage.
0.00 ... 50.00 %
Disabled / uint16
Selects whether the temperature-dependent
parameters (such as stator or rotor resistance) of the
motor model adapt to actual (measured or estimated)
temperature or not.
See parameter group
for
selection of temperature measurement sources.
Motor model
temperature
adaptation
97.15
0
Temperature adaptation of motor model disabled.
Disabled
1
Estimated temperature (
) used for adaptation of motor model.
Estimated
temperature
2
Measured temperature 1 (
) used for adaptation of motor model.
Measured
temperature 1
3
Measured temperature 2 (
) used for adaptation of motor model.
Measured
temperature 2
Off / uint16
Activates hexagonal motor flux pattern in the field
weakening area, i.e. above the limit defined by
parameter
97.19 Hexagonal field weakening point
Note: This parameter is only effective in scalar motor
control mode.
See also section
Hexagonal field
weakening
97.18
0
The rotating flux vector follows a circular pattern.
Off
1
The flux vector follows a circular pattern below, and a
hexagonal pattern above, the hexagonal field
weakening point (
).
On
120.0 % / real32
Defines the activation limit for hexagonal field
weakening (in percent of the field weakening point, i.e.
the frequency at which maximum output voltage is
reached). See parameter
.
Note: This parameter is only effective in scalar motor
control mode.
Hexagonal field
weakening point
97.19
1 = 1 % / 1000 = 1 %
Activation limit for hexagonal field weakening.
0.0 ... 500.0 %
0.0 % / real32
Unfiltered motor torque in percent of the nominal
motor torque.
Note: This parameter is read-only.
Motor torque
unfiltered
97.32
- / -
Unfiltered motor torque.
For scaling, see parameter
-1600.0 ... 1600.0 %
5.00 ms / real32
Defines a filtering time for estimated speed See the
diagram on page
.
Speed estimate
filter time
97.33
1 = 1 ms / 100 = 1 ms
Filtering time for estimated speed.
0.00 ... 100.00 ms
Parameters 531
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...