Parameters and firmware blocks
85
12.13
DI INVERT MASK
(see above)
Inverts status of digital inputs as reported by
. For example, a value of 0b000100
inverts the status of DI3 in the signal.
0b000000…0b111111
DI status inversion mask.
12.14
DIO2 F MAX
(see above)
Defines the maximum value for frequency input (when
is set to
).
3…32768 Hz
Maximum DIO2 input frequency.
12.15
DIO2 F MIN
(see above)
Defines the minimum value for frequency input (when
).
3…32768 Hz
Minimum DIO2 input frequency.
12.16
DIO2 F MAX SCALE
(see above)
Defines the real value that corresponds to the maximum frequency input value defined by
parameter
.
-32768…32768
Real value corresponding to value of parameter
12.17
DIO2 F MIN SCALE
(see above)
Defines the real value that corresponds to the minimum frequency input value defined by
parameter
. See parameter
-32768…32768
Real value corresponding to value of parameter
DIO2
(real)
DIO2
(Hz)
DIO2
(real)
DIO2
(Hz)