Page 50 of 56
III.
Steps to setup a new lock
(Steps 1-4 must be completed in that order)
1.
Reset the lock to factory defaults. Press and hold the reset button for about 10 seconds. When the LED starts flashing,
release the reset button and press the '#' key while the LED is still flashing. The lock will beep 3 times, indicating the reset
was successful. Lock firmware versions other than v8.6 may require a slightly different procedure for reset.
2.
Change the master code (For example, change to
223344)
# 123456 # 11 # 223344 # 223344 #
3. Enable daylight saving (optional)
# 223344 # 31 #
4. Set lock time (For example, set time as January 23, 2008, 2:45PM)
#
223344 # 88 # 1201231445#
(2 digit year, 2 digit month, 2 digit day, then time in 24 clock format)
5. Add user code (For example, add user keypad code 1357 to the lock)
#
223344 # 01 # 1357 # # #
6. Add iButton key (Optional)
#
223344 # 01 #
iButton key touch lock reader # #
7. Set any schedules for user codes, iButton keys, or automatic lock functions (Optional)
IV.
Types to operate the lock:
•
Keycode
: User Code, #
•
iButton
: iButton key touch lock reader
•
Keypad
: iButton touch lock reader, LED lights green, enter user code, #
•
One time service code
: One time code, #
•
Manual key
: Turn the override key 90 degree clockwise, then turn the handle
V.
Terms:
Master code:
The master code puts the lock into a programming mode.
It will not lock/unlock the lock
. When
#, master code, #
is
entered, the red LED indicates the lock is in a programming mode. If more than 6 seconds pass in between programming entries, the
lock will return to normal operational state. For maximum security
it is necessary to change the default master code of 123456
.
Installer code:
Installer code is a default temporary code (
0
) for installer testing the lock. The code will be deleted after the first new
user code is added to the lock.
User code:
User code is the Normal code for the day-to-day operations.
Service code:
Service Codes are used for a special purpose such as maintenance personnel or vendors. Service Code
only grants one time access. Total of 10 sets of service codes can be programmed to each lock.
Index #*:
Each code or iButton will be associated with a unique number, called the index# (or slot#). The Index # is auto generated
by lock and starts with 000. The highest Index# will be 299; therefore up to 300 users can be added to each lock.
*
Please log the user code along with its index # for future reference. It is required to delete particular users later should you need to
.
Passage mode:
When Passage Mode is enabled, the lock will stay in unlocked after first valid entry. Re-enter a valid entry to lock
back.
Storehouse mode:
for each valid entry, lock will automatically lock back in 5 seconds.
Lockout:
Enable the Lockout mode will freeze the lock at its current state (Lock or unlock), temporarily disable all the user codes and
iButton keys. Re-enter the function code 99 to disable the lockout mode, and resume
Reset:
All settings will be restored to factory default settings.
VI.
Functions
How to change programming code (and not delete existing user codes)
θ
Function Code: 11#
¬
{#}+{default master code#}+{11#}+{new master code#}+{new master code#}
Summary of Contents for Eternity 4