26
User Manual v1.4.3
HYDRODIGIT
Name
Type
Default
Minimum Maximum Description
Index
Alarm
Flags 1
Uint8_t
0x00
0x00
0x3F
Bit 0: Water leak
Bit 1: wrong installation
Bit 2: Overflow
Bit 3: Burst
Bit 4: Reverse flow
Bit 5: Low battery
1
Alarm
Flags 2
Uint8_t
0x00
0x00
0xC0
Bit 0: Reserved
Bit 1: Reserved
Bit 2: Reserved
Bit 3: Reserved
Bit 4: Reserved
Bit 5: Reserved
Bit 6: EEPROM Error
Bit 7: Coil Error
2
QMax Alarm
Date
Uint32_t
0x00
0x00
0xFFFFFFFF yy/mm/dd
3 – 6
Wrong
installation
alarm date
Uint32_t
0x00
0x00
0xFFFFFFFF yy/mm/dd
7 – 10
Burst alarm
date
Uint32_t
0x00
0x00
0xFFFFFFFF yy/mm/dd
11 – 14
Reverse flow
alarm date
Uint32_t
0x00
0x00
0xFFFFFFFF yy/mm/dd
15 – 18
Answer:
HEADER property
Data
Fct
C/R/A
Err
Chain
Len
Device type
AlarmData
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
18 bytes
0x28
0x01
0x00
0x00
0x13
0x05
The field AlarmData is defined as follows:
The Err field can have the following meanings:
0x00 – No error
0x02 – Error on the device type
0x04 – Error on the command length.
SET_ALARM_DATA (0x29)
This command is used to set the alarm flags
From meter to Application Server:
HEADER property
Data
Fct
C/R/A
Err
Chain
Len
Device type
Alarm Flags
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
2 byte
0x29
0x00
0x00
0x00
0x03
0x05