TagRunners – Communication Protocol v1.4
- 8 -
Data Capture
for Workforce
in Motion
Code ID
0x50-0x51
Description
Lock/Unlock Scan engine
Payload
1 byte :
{0 = Unlock, 1 = Lock}
Response
1 byte : {Bit 0 : Success}
Code ID
0x54-0x55
Description
Get/Set dock use
Payload
Get : None
Set : 1 byte :
{0 = Disable communication via RS232 dock
1 = Enable}
Response
Get : 1 byte :
{0 = Disable communication via RS232 dock
1 = Enable}
Set : 1 byte :
{Bit 0 : Success}
Code ID
0x56-0x57
Description
Get/Set In charge behavior
Payload
Get : None
Set : 1 byte :
{shutdown timeout (0 = leave current timeouts (default), 255 = infinity)}
Response
Get : 1 byte :
{shutdown timeout (0 = leave current timeouts (default), 255 = infinity)}
Set : 1 byte :
{Bit 0 : Success}
Remarks
When scanner in charge, the shutdown timers can be modified