CSIOPCServer
Description:
Reflects the total number of final storage values that need to be
collected from final storage area one of a classic datalogger if collection is
active for that area. If collection is not active for that area, this statistic
reflects the last count that should have been collected.
6.3.2.22 FS1 Collected
Type:
uint4
Applies to:
21X, CR7X, CR10, CR10X, CR500, CR510, CR23X
Description:
Reflects the total number of final storage values that have been
collected from a classic dataloggers final storage area one.
6.3.2.23 FS2 to Collect
Type:
uint4
Applies to:
CR10, CR10X, CR510, CR23X
Description:
Reflects the total number of final storage values that need to be
collected from final storage area two of a classic datalogger if collection
is active for that area. If collection is not active for that area, this statistic
reflects the last count that should have been collected.
6.3.2.24 FS2 Collected
Type:
uint4
Applies to:
CR10, CR10X, CR510, CR23X
Description:
Reflects the total number of final storage values that have been
collected from a classic dataloggers final storage area two.
6.3.2.25 Logger Ver
Type:
uint4
Applies to:
21X, CR7X, CR10, CR10X, CR500, CR510, CR23X
Description:
Relates the datalogger interface version as given in the
datalogger’s response to the “A” command.
6.3.2.26 Watchdog Err
Type:
uint4
Applies to:
21X, CR7X, CR10, CR10X, CR500, CR510, CR23X
Description:
Relates the datalogger watch dog error count as given in the
classic datalogger’s response to the “A” command.
13