Raven II Digital Cellular Modem
8
To allow contacting the station throughout the day, the transceiver can be
turned on for the first 10 minutes of each hour:
;{CR10X}
;
*Table 1 Program
01: 10.0
Execution Interval (seconds)
01: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
41
Set Port 1 High
02: If time is (P92)
1:
10
Minutes (Seconds --) into a
2:
60
I
nterval (same units as above)
3:
51
Set Port 1 Low
*Table 2 Program
02: 0.0
Execution Interval (seconds)
*Table 3 Subroutines
End Program
Or one might want to power the transceiver for one hour at 10 a.m. and at 10
p.m.
;{CR10X}
;
*Table 1 Program
01: 10.0
Execution Interval (seconds)
01: If time is (P92)
1:
600
Minutes (Seconds --) into a
2:
720
Interval (same units as above)
3:
41
Set Port 1 High
02: If time is (P92)
1:
660
Minutes (Seconds --) into a
2:
720
Interval (same units as above)
3:
51
Set Port 1 Low
*Table 2 Program
02: 0.0
Execution Interval (seconds)
*Table 3 Subroutines