CARROLL TOUCH
Appendix B - Smart-Frame Protocol II Function Reference
Touch System Programmer’s Guide
B-17
The touch system responds with the following report:
E0 02 01 21 FF
This report indicates that fewer parameters byte were received than
expected via Cmderr (the
01
byte).
If function 09 is not defined and the host sends the SetReportProperties
(21H) command as follows:
66 02 21 09 FF
The touch system responds with the following report:
E0 05 00 21 09 00 00 FF
This report indicates no errors in Cmderr and indicates that function 09
is not defined (that is, has a version number of 00) in the last
00
. The
reporting mode parameter is undefined and reported as
00
in the next
to last
00
.
If function 01 is defined and the continuous reporting mode (02) is valid
for that particular function and the host sends the SetReportProperties
(21H) command as follows:
66 03 21 01 02 FF
The touch system responds with the following report:
E0 05 00 21 01 02 01 FF
This report indicates no errors in Cmderr and reports that the reporting
mode for function 01 is now continuous (
02
). It also reports that the
version number for function 01 is
01
.
If function 05 is defined and the continuous reporting mode (02) is
invalid for that particular function and the host sends the
SetReportProperties (21H) command as follows:
66 03 21 05 02 FF
The touch system responds with the following report:
E0 05 02 21 05 01 01 FF
Summary of Contents for TouchSystems CarrollTouch Prog
Page 1: ...CARROLL TOUCH TOUCH PRODUCTS an company AMP Touch System Programmer s Guide ...
Page 11: ...Table of Contents CARROLL TOUCH viii ...
Page 13: ...Table of Contents CARROLL TOUCH x ...
Page 17: ...Welcome CARROLL TOUCH xiv Touch System Programmer s Guide ...
Page 41: ...Chapter 3 General Programming Issues CARROLL TOUCH 3 12 Touch System Programmer s Guide ...
Page 57: ...Chapter 4 Smart Frame Protocol CARROLL TOUCH 4 16 Touch System Programmer s Guide ...
Page 237: ...Appendix D CTKERN Function Reference CARROLL TOUCH D 42 Touch System Programmer s Guide ...