Integrated Switching Power Supply 

8

 

Command 

Function 

Feedback Example 

When x =1~5, clear the data of the 
Group x. 

Clear F[x]. 

QueryGroup[x]. 

When x = NULL, query all groups. 

Out    01  02  03  04  05  06  07 
08 09 10 11 12 

Vm1    12 12 12 12 12 12 12 
12 12 12 12 12 

Vm2    XX XX XX XX XX XX 
XX XX XX XX XX XX 

……

 

When x = 1~5, query the group x. 

Out    01  02  03  04  05  06  07 
08 09 10 11 12 

Vm[x]    12 12 12 12 12 12 12 
12 12 12 12 12 

%0911. 

Restore Factory Defaults. 

Factory Default 

/*Name; 

Query the manufacturer. 

XXX 

/*Type; 

Query the product model 

PSU12 

/^Version; 

Query the software version. 

V x. x. x 

Baud[x]. 

Set the baud rate as x. x = 1200, 
2400,4800,9600,19200,38400, 
57600,115200.   

When x =NULL, the default baud 
rate is 9600. 

Baud [x] not change. 

Baud [y] change to [x]. 

%0964. 

Query the IP address. 

IP XXXX 

 

Note: 

After sending the 

“Output/[x]V/[y].” 

to change the output voltage, the 

corresponding output channel will be switch off, the command “

[x]@.” 

should be sent 

to switch on this output channel again.

 

 

 

Summary of Contents for PSU12

Page 1: ...PSU12 Integrated Switching Power Supply All Rights Reserved Version PSU12_2016V1 0 User Manual ...

Page 2: ... the properties of the trademark owner No part of this publication may be copied or reproduced without the prior written consent FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been tested and found to comply with the limits for a Class ...

Page 3: ... or install this product near water l Do not put any heavy items on the extension cable in case of extrusion l Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards l Install the device in a place with fine ventilation to avoid damage caused by overheat l Keep the module away from liquids l Spillage into the housing may result i...

Page 4: ...tion Procedure 4 4 System Operations 5 4 1 Front Panel Buttons 5 4 2 RS232 Control 5 4 2 1 Installation uninstallation of RS232 Control Software 5 4 2 2 Basic Settings 5 4 2 3 RS232 Communication Commands 6 4 3 Web based GUI Control 9 4 3 1 Control Menu 10 4 3 2 Voltage Setting Menu 11 4 3 3 Network Menu 11 4 3 4 Password Menu 12 4 3 5 Web based GUI Update 13 5 Specification 14 6 Panel Drawing 15 ...

Page 5: ...itch on rear panel RS232 command or web based GUI 1 2 Features l Double input channel designed for ensuring the stable AC source l Total 12 output channels and each channel has three kinds of output voltage 5 12 24VDC can be selected l Output channels can be switch on off by via the front panel buttons RS232 commands or Web based GUI l Output voltage 5 12 24VDC can be selected via the TACT Switch ...

Page 6: ...e corresponding channel and the corresponding LED will turn green and keep on Note Pictures shown in this manual are for reference only different model and specifications are subject to real product 2 2 Rear Panel FIRMWARE 01 02 03 04 05 06 07 08 09 10 11 12 AC 2 AC 1 PSU12 1 2 3 C 24V DC 12V 5V SELECT AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V...

Page 7: ...indicator of the current selected output voltage will blink slowly and and keep on RS232 Serial port 3 Pin phoenix connector connect with a control device such as PC to control the product via RS232 commands TCP IP Ethernet port connect with PC to control the product via Web based GUI AC1 AC2 2 AC input channels Input voltage is AC100 240V Note Pictures shown in this manual are for reference only ...

Page 8: ...e DC ports on rear panel Step2 Connect the PC to the RS232 port on rear panel Step3 Connect the PC to the TCP IP port on the rear panel Step4 Connect the power cables to the one or both of AC1 and AC2 input port AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V ...

Page 9: ...put channel switching button on front panel 4 2 RS232 Control Connect a PC to the RS232 port on the rear panel and then install the RS232 control software on the PC the product can be controlled by sending RS232 commands via the RS232 control software 4 2 1 Installation uninstallation of RS232 Control Software l Installation Copy the control software file to the computer connected with the product...

Page 10: ...ds Communication protocol RS232 Communication Protocol Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none Command Function Feedback Example All Switch on all output channels All Open All Switch off all output channels All Closed x Switch on the output channel x x 1 12 x Open x Switch off the output channel x x 1 12 x Closed Parameter Configuration area Monitoring area indicates if the command se...

Page 11: ...pen 02 Closed 03 Closed When x 1 12 query the on off status of the output channel x x Open x Closed Save x Save the current on off status to Group x x 1 5 Save To F x Recall x Invoke the on off status of Group x x 1 5 If Group x has no data the feedback information F x no data If Group x has data the feedback information Recall From F x Out 01 02 03 04 05 06 07 08 09 10 11 12 State S S S S S S S S...

Page 12: ...2 12 12 12 12 12 12 12 12 12 12 0911 Restore Factory Defaults Factory Default Name Query the manufacturer XXX Type Query the product model PSU12 Version Query the software version V x x x Baud x Set the baud rate as x x 1200 2400 4800 9600 19200 38400 57600 115200 When x NULL the default baud rate is 9600 Baud x not change Baud y change to x 0964 Query the IP address IP XXXX Note After sending the...

Page 13: ... via web based GUI It allows users to interact with the product through graphical icons and visual indicators 1 Connect a PC to the TCP IP port on the rear panel and set its network segment to the same as the default IP of the product 192 168 0 178 port No 4001 2 Type 192 168 0 178 in your browser it will enter the log in interface shown as below Same network segment as the product ...

Page 14: ...and password user default setting on the log in interface and then click Login to enter Control menu shown as below l Select the ON OFF to switch on off the output channel l Click the All On to switch on all output channels l Click the All Off to switch off all output channels ...

Page 15: ... Menu Click Voltage Setting on the top of page to enter voltage setting menu shown as below In this interface you can select 5V 12V or 24V for each output channel 4 3 3 Network Menu Click Network on the top of page to enter network setting menu shown as below ...

Page 16: ...ic or static IP mode can be selected Under static IP mode IP address and subnet mask gateway can be set and make sure the IP addresses are different to avoid IP conflict 4 3 4 Password Menu Click Password on the top of page to enter password menu shown as below ...

Page 17: ...s online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified password will be available only after rebooting to log in the configuration interface After that click Administration at the source menu to get to Upload Program as shown below Select the desired update file and press Apply it will start upgrading then ...

Page 18: ...imum output power consumption of signal channel 15W Total output power consumption 180W Control Part Buttons Control Front Panel 01 12 total 12 buttons Rear Panel Total 12 TACT Switches named SELECT RS232 Control RS232 port 3 Pin phoenix connector Baud rate support 1200 2400 4800 9600 default 19200 38400 57600 115200 Web based GUI Control TCP IP port RJ45 Default IP 192 168 0 178 Port No 4001 Gene...

Page 19: ...AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 437 mm 44 mm ...

Page 20: ...t RS232 communication parameters Fail or loose connection Make sure the connection is good Broken RS232 port Send it to authorized dealer for checking Cannot control the device by front panel buttons while can control it through RS232 port The front panel buttons are broken Send it to authorized dealer for repairing Cannot control the device via Web based GUI The IP address of control PC and TCP I...

Page 21: ...buttons web based GUI If your problem persists after following the above troubleshooting steps seek further help from authorized dealer or our technical support ...

Page 22: ...actory applied serial number has been altered or removed from the product l Damage deterioration or malfunction caused by l Normal wear and tear l Use of supplies or parts not meeting our specifications l No certificate or invoice as the proof of warranty l The product model showed on the warranty card does not match with the model of the product for repairing or had been altered l Damage caused b...