81
NAME VALUE
DESCRIPTION
RS232
switch COM to RS232
interface
<other than RS232>
switch COM to RS485
Yes
Enable control PT device
camctrl
<other than yes>
Disable control PT device
baud
<integer>
set baud rate of COM
data
<integer>
set data bits of COM
1
set 1 stop bit of COM
stop
2 <other than 1>
set 2 stop bits of COM
None
set parity check of COM to none
Odd
set parity check of COM to odd
parity
Even
set parity check of COM to even
up
<text string shorter than 80 characters> tilt up command string of COM
down
<text string shorter than 80 characters> tilt down command string of COM
left
<text string shorter than 80 characters> pan left command string of COM
right
<text string shorter than 80 characters> pan right command string of COM
home
<text string shorter than 80 characters> home command string of COM
Camera custom command configuration URL
URL: /setup/command.cgi
NAME VALUE
DESCRIPTION
str1
<text string shorter than 8 characters> button name of custom command 1 of COM
str2
<text string shorter than 8 characters> button name of custom command 2 of COM
str3
<text string shorter than 8 characters> button name of custom command 3 of COM
str4
<text string shorter than 8 characters> button name of custom command 4 of COM
str5
<text string shorter than 8 characters> button name of custom command 5 of COM
com1
<text string shorter than 80 characters> custom command 1 of COM
com2
<text string shorter than 80 characters> custom command 2 of COM
com3
<text string shorter than 80 characters> custom command 3 of COM
com4
<text string shorter than 80 characters> custom command 4 of COM