Vector Sensor Reference Manual
67
The virtual circuit command has the following form.
$JCONN,p<CR><LF>
Where the connection type, ‘p’, may be one of the following.
p
Description
AB
Specify ‘AB’ in order to connect the A port to the B port
X
Once a virtual circuit has been established, to remove the
virtual circuit, specify ‘X’ in this command to return the
current port to normal
6.3.9
$JDIFF
This command is used to change the differential mode of the Vector Sensor receiver. The default
differential mode is SBAS (WAAS).
The structure of this command follows.
$JDIFF,diff<CR><LF>
Where the differential mode variable, ‘diff’, has one of the following values.
diff
Description
OTHER
Specifying OTHER instructs the Vector Sensor to use external
corrections input through the opposite port from which you are
communicating
BEACO
N
Specifying BEACON instructs the Vector Sensor to use corrections
from the internal SBX beacon engine
WAAS
Specifying WAAS instructs the Vector Sensor to use SBAS
corrections
NONE
In order for the Vector Sensor to operate in autonomous mode,
the NONE argument may be specified in this command.
6.3.10
$JK
This command is used by the Vector Sensor to enable subscriptions for various features.
This command will have the following format.
$JK,x…<CR><LF>
Where ‘x…’ is the subscription key provided by CSI Wireless and is 10 characters in length.
If you send the $JK command without a subscription key as follows, it will return the expiry date
of the subscription.
$JK<CR><LF>