24
COMMAND
DESCRIPTION
PARAMETERS
SET UART 1 DATA BITS N1
Set the number of data bits for RS-
232.
Available values for
N1
:
0
[5 Bits]
1
[6 Bits]
2
[7 Bits]
3
[8 Bits]
GET UART 1 DATA BITS
Show the current RS-232 data bits
setting.
SET UART 1 PARITY N1
Set the parity for RS-232.
Available values for
N1
:
0 [None]
1 [Odd]
2 [Even]
GET UART 1 PARITY
Show the current RS-232 parity
setting.
SET OUT A AUTOMATION N1 MODE N2
Enable or disable each automated
action slot.
N1
= 1 ~ 8
[Slot Number]
Available values for
N2
:
ON [Enable]
OFF [Disable]
GET OUT A AUTOMATION N1 MODE
Show the current state of
automated action slot N1.
N1
= 1 ~ 8
[Slot Number]
SET OUT A AUTOMATION N1 COMMAND N2
Set the RS-232 string to send when
automated action N1 is activated.
N1
= 1 ~ 8
[Slot Number]
N2
= {string} [64 Chars Max]
GET OUT A AUTOMATION N1 COMMAND
Show the current RS-232 command
string assigned to slot N1.
N1
= 1 ~ 8
[Slot Number]
Summary of Contents for PUV-1605S-TXWP