Click on library
RxPDO
via menu [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT
™
)
→
Box1 (VLT
™
Decentral Access
Module)
→
Drive2 (VLT
™
ISD 510 Integrated Servo Drive)
→
Module1 (Library PDO)
→
Library RxPDO].
Select all entries
Lib pdo rx1
to
Lib pdo rx9
on the right side of the window.
Right-click and select
Change Multi Link...
.
In the
Attach Variable 36.0 Byte(s) (Output)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.RPDO].
Click on
OK
.
Right-click on
WcState
via menu [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT
™
)
→
Box1 (VLT
™
Decentral Access
Module)
→
Drive2 (VLT
™
ISD 510 Integrated Servo Drive)
→
WcState] and select
Change Link...
.
In the
Attach Variable State (Input)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAx-
is.WcState].
Click on
OK
.
Right-click on
State
via menu [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT
™
)
→
Box1 (VLT
™
Decentral Access
Module)
→
Drive2 (VLT
™
ISD 510 Integrated Servo Drive)
→
InfoData] and select
Change Link...
.
In the
Attach Variable State (Input)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.State].
Click on
OK
.
Right-click on
netId
via menu [I/O-Configuration
→
I/O Devices Device1 (EtherCAT
→
)
→
Box1 (VLT
®
Decentral Access Mod-
ule)
→
Drive2 (VLT
→
ISD 510 Integrated Servo Drive)
→
InfoData
→
AdsAddr] and select
Change Link...
.
In the
Attach Variable netId (Input)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.Ams-
NetId].
Click on
OK
.
Right-click on
Port
via [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT
→
)
→
Box1 (VLT
→
Decentral Access Module)
→
Drive2 (VLT
→
ISD 510 Integrated Servo Drive)
→
InfoData
→
AdsAddr] and select
Change Link...
.
In the
Attach Variable port (Input)
window, select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.Node-
Number].
Click on
OK
.
6.11.13 Transferring the Mappings back to the PLC Program
To transfer the mappings back to the PLC program, select
Activate Configuration...
in menu item
Actions
.
After a rebuild in TwinCAT
®
PLC Control, the TwinCAT
®
configuration is according to
(here
myAxis
and
mySecondAxis
are instances of
AXIS_REF_DDS
,
myPSM
is an instance of
PSM_REF
, and
myDAM
is an instance of
DAM_REF
). The concrete addresses
can be different.
e3
0b
h5
20
.1
0
Illustration 73: TwinCAT
®
Configuration: I/O Mapping of 2 Servo Drives, 1 PSM 510, and 1 DAM 510
AQ262449648484en-000101 / 175R1135
104 | Danfoss A/S © 2020.08
Commissioning
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide