5
Data Input
Data Input is in the form of System and Label Formatting commands, where <STX>KcRI and
<STX>KcQQQ support the entries that are shown in Menu mode. The RFID database file (RFID_DB)
resides on the Y module. It stores RFID information and should not be deleted. If not found at power-up
then factory defaults will be set.
<STX>KcRIa
configures the RFID interface, as noted below:
Value
Units / Interpretation
RFID Configuration Definition / Function
D = Disable
Disables the RFID module. (“N” is also a valid disabler.)
H = HF
Enables the RFID module for HF (Securakey).
U = UHF
Enables the RFID module for UHF Class 1 (Alien).
M
n
where
n
:
M = UHF
Enables the RFID module for UHF Multi-Protocol (Samsys).
AI
hh
where
hh
:
2-Chararacter Hex ID
Sets the Application Family Identifier (AFI), (HF only)
AL
n
where
n
:
E = Enable,
D = Disable
Allows locking the AFI after writing (HF only)
DI
hh
where
hh
:
2-Chararacter Hex ID
Sets the Data Storage Format Identifier (DSFID), (HF only)
DL
n
where
n
:
E = Enable,
D = Disable
Allows locking the DSFID after writing (HF only)
S
hh
where
hh
:
2-Chararacter Hex ID
Sets the Electronic Article Surveillance (EAS) set, representing
the manufacturer’s code. (HF only)
L
hh
where
hh
:
2-Chararacter Hex ID
Sets the Lock Code (Alien UHF only)
R
n
where
n
:
0 – 9
Sets the number of retries for RFID functions
W
n
where
n
:
E = Enable,
D = Disable
Allows locking the tag after writing.
E
n
where
n
:
E = Enable,
D = Disable
Allows erasures of the tag on error (HF only)
P
xxx
where
xxx
:
Is a 3-digit value
Sets the tag encoding position: A value of 0.00 causes the print
position to be used; or, a value greater than 0 causes the
presented position to be used. (Subject to change.)
T
n
where
n
:
0 = ISO 15693
1 = Texas Instruments
2 = Philips
3 = ST Micro LRI 512
4 = ST Micro LRI 64
Establishes the tag type (HF only).
N
n
where
n
:
64 = 64-bit
96 = 96-bit
Sets the UHF tag data size (Samsys UHF only).
U
n
where
n
:
0 = EPC 0
1 = EPC 0+ Matrics
2 = EPC 0+ Impinj
3 = EPC 1
4 = ISO 18000-6A
5 = ISO 18000-6B
6 = UCODE EPC 1.19
7 = EM 4022/4222
8 = Gen 2
Sets the UHF tag type (Samsys UHF only).
V
n
where
n
:
Is a value from -4 to +4 Adjusts the power, in dBmn (Samsys UHF only).