b) Configuration with 12 switch modules and 3 distribution amplifier modules:
Index 1: switch module in the first slot, primary input port ("In A")
Index 2: switch module in the first slot, secondary input port ("In B")
(…)
Index 31: "logical" switch module in the sixteenth slot, primary input port
Index 32: "logical" switch module in the sixteenth slot, secondary input port
Index 33: switch module in the first slot, output port ("Out")
(…)
Index 48: "logical" switch module in the sixteenth slot, output port
Index 49: distribution amplifier module in the fourteenth slot, input port
Index 50: distribution amplifier module in the fifteenth slot, input port
Index 51: distribution amplifier module in the sixteenth slot, input port
5.9.4.3.9.1
.application.portTable.portEntry.portIndex
OID:
.1.3.6.1.4.1.21035.41.2.9.1.1
.x
Syntax:
INTEGER32 (1..255)
Access:
not-accessible
Description:
A unique value for each table entry ranging between "
1
" and the
number of entries (defined by .numberOfPorts, chapter 5.9.4.3.8).
5.9.4.3.9.2
.application.portTable.portEntry.poEnable
OID:
.1.3.6.1.4.1.21035.41.2.9.1.2
.x
Syntax:
INTEGER {disabled (1), enabled (2)}
Access:
read-write
Description:
Events possibly caused by the port are (or can be) enabled or dis-
abled. Additionally this setting influences the switching behavior of
a device with applied sensing switch modules or digital signal
switch modules in Auto Mode with activated autonomous
switching functionality; please refer to chapter 5.1.3.
Note:
It is possible to enable or to disable any of the ports in the .portTable but this
makes sense only for ports that are capable of generating port specific events.
The factory setting is "
2
" (enabled) for all ports.
5.9.4.3.9.3
.application.portTable.portEntry.poType
OID:
.1.3.6.1.4.1.21035.41.2.9.1.3
.x
Syntax:
INTEGER32 (0..255)
Access:
read-only
Description:
The functionality of the port, possible values:
"
0
" common output port of a switch module;
"
1
" primary input port of a module
(switch module or distribution amplifier module);
"
2
" secondary input port of a switch module.