PCI 703 User Manual
Eagle Technology - Data Acquisition
Eagle Technology © Copyright 2001-2004 – www.eagledaq.com
22
Channel
Long
Channel
0: DAC Channel 0
1: DAC Channel 1
Frequency
Long
Actual value written to counter
ClkSrc
Long
Clock source
0: Internal 20 MHz
1: Internal 100 KHz
2: External Clock
GateSrc
Long
Gate Source – Ignored
Continuous
Long
Mode
Length
Long
Number of samples in buffer
uVoltage
Pointer to a long buffer
Buffer filled with micro voltages
Return
Long
Error Code
API-CALL
Long EDRE_DAControl (ulng Sn, ulng Channel, ulng Command)
Parameter
Type
Description
Sn
Unsigned long
Board’s serial number
Channel
Unsigned long
Channel
0: DAC Channel 0
1: DAC Channel 1
Command
Unsigned long
Command Code
0: NULL
1: Start process
2: Stop process
3: Pause process
4: Continue process
Return
Long
Error Code
ACTIVEX CALL
Long EDREDAX.Control (long Channel, long Command)
Parameter
Type
Description
Channel
Long
Channel
0: DAC Channel 0
1: DAC Channel 1
Command
Long
Command Code
0: NULL
1: Start process
2: Stop process
3: Pause process
4: Continue process
Return
Long
Error Code