Data definition as specified:
Name
Value (Byte
0)
Value (Byte
0)
Value (Byte 0)
VISCA
command
0x01
0x00
Stores the VISCA command.
VISCA inquiry 0x01
0x10
Stores the VISCA inquiry.
VISCA reply
0x01
0x11
Stores the reply for the VISCA
command and VISCA
inquiry, or VISCA device setting
command.
VISCA device
setting
command
0x01
0x20
Stores the VISCA device setting
command.
Control
command
0x02
0x00
Stores the control command.
Control reply 0x02
0x01
Stores the reply for the control
command.
Payload length
Valid data length in Payload (1~16), is command length.
For example, when valid data length is 16 byte
Byte 2 : 0x00
Byte 3 : 0x10
Controller will save sequence number of each command, when one command sent, the sequence
number of the command will add 1, when the sequence number becomes the max value, it will
change to 0 for next time. The peripheral equipment will save sequence number of each command,
and return the sequence number to the controller.
Payload
According to Payload type, the following data will be saved.
●
VISCA command
○
Save VISCA command packet
●
VISCA inquiry
○
Save VISCA message packet
●
VISCA reply
○
Save VISCA return packet
●
VISCA device setting command
○
Save VISCA equipment setting command packet.
Control command
38
WWW.EVERETIMAGING.COM