27
ENGLISH
Tab. 10/g
LOGIC “S”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
reverses at
closure
reverses at
closure
recloses leaves
immediately
stops operation
reverses at
closure
continues to open
and recloses
immediately
stops and opens
at release
(saves CLOSE)
OPEN IN PAUSE
recloses leaves
immediately ()
recloses leaves
immediately
recloses leaves
immediately
stops operation
no effect
stops and, at
release, closes
stops and, at
release, closes
CLOSING
reopens leaves
immediately
reopens leaves
immediately
no effect
stops operation
no effect
reverses at opening
(see 2
nd
level
prog.) and closes
immediately at end
stops and opens
after release and
closes immediately
at end
BLOCKED
closes leaves
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 10/h
LOGIC “SP”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
()
stops operation recloses leaves
immediately
stops operation
reverses at
closure
continues to open
and recloses
immediately
stops and opens after
release and closes
immediately at end (OPEN
stops - saves CLOSE)
OPEN IN PAUSE
recloses leaves
immediately ()
recloses leaves
immediately
recloses leaves
immediately
stops operation
no effect
stops and, at
release, closes
stops and, at
release, closes
CLOSING
stops operation
stops operation
no effect
stops operation
no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release (saves
CLOSE)
BLOCKED
restarts moving in
opposite direction.
Always closes after
STOP
restarts moving in
opposite direction.
Always closes after
STOP
recloses leaves
immediately
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 10/e
LOGIC “SA”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
no effect ()
no effect
recloses leaves
immediately
stops operation
reverses at
closure
no effect
stops and opens
at release (saves
CLOSE)
OPEN IN PAUSE
recloses leaves
immediately ()
recloses leaves
immediately
recloses leaves
immediately
stops operation
no effect
recharges
pause time
(CLOSE disabled)
recharges
pause time
(CLOSE disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
no effect
stops operation
no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release (saves
CLOSE)
BLOCKED
closes leaves
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 10/f
LOGIC “AP”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
()
stops operation recloses leaves
immediately
stops operation
reverses at
closure (saves
OPEN)
no effect
stops and opens
at release
(OPEN stops -
saves CLOSE)
OPEN IN PAUSE
stops operation
()
stops operation recloses leaves
immediately
stops operation
no effect
recharges
pause time
(CLOSE disabled)
recharges
pause time
(CLOSE disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
no effect
stops operation
no effect
reverses at opening
(see 2
nd
level
prog.)
stops and opens
at release
(OPEN stops -
saves CLOSE)
BLOCKED
closes leaves
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
() if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
() if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
() if the cycle began with OPEN-B (released leaf), both leaves are activated at opening