19
RS-232 SERIAL CONTROL
RS-232 Features
RS-232 remote functions are used to control of this product’s features. Features
include input to output routing, EDID storage, EDID management, etc. These
functions are available only through the use of the serial port.
Functions Syntax
The syntax for each function is always the same:
Character as the start flag → Function name → Space ( _ ) as function name end
flag → Parameter 1 → Space → Parameter n → Carriage Return ( \r ) →
Sample:
#FunctionName_param1_param2_param3_param4...\r
Syntax is NOT case sensitive.
Function list
EDID Management
Function
Description
#EDIDDSTOLO
Read downstream EDID and stores into a Local EDID
#EDIDDSTOBA
Read downstream EDID and stores in EDID Bank
#EDIDBATOLO
Read downstream EDID and stores in any Local Input
#EDIDDETOLO
Sets Local EDID to Default EDID
#LOCKEDID
Secures Local EDID
#LOEDIDTOLO
Load EDID file using serial port to one of the local memories
#PRLOEDID
Read Input Local EDID and sends to serial port
#PRDSEDID
Read downstream EDID and sends to serial port
#PRBAEDID
Read downstream EDID from bank and sends to serial port
#PREDIDST
Prints EDID details