DCX Series User’s Guide
Version 2.11 Rev. 0 13 August 2013
6
Reset Record Size Command
Version Command
\ x x d r s
xx
data size
min=4, max=40
d
include the date when saving data
0=no, 1=yes
r
include the reader id when saving data
0=no, 1=yes
s
include the reader description when saving data
0=no, 1=yes
This command clears all data in the reader, and sets the record size. The record size must be set to the largest size of any
data that you will be storing. It is ok to read card data that is smaller than this size, but any card data larger than this size will
be rejected.
When reading proximity style cards, you will need to program the reader to the field data that you want to read off of the
card, and the length of each of these fields when they are converted into decimalized numbers. The total length of
the fields which are converted cannot be larger than the maximum record size setting. See the proximity formatting
commands for more information.
V
This command returns the firmware version loaded in the reader.
Set Time Command
+ yy mm dd hh mm ss x
yy
year
mm
month
dd
day
hh
hour (24 hour format, 00 thru 23)
mm
minutes
ss
seconds
x
use a 1 always
This command sets the date and time in the reader.