I - 7 5 5 0 E Q u i c k S t a r t
( V e r s i o n 1 . 0 0 , J u n e / 2 0 1 4 )
P A G E
:
7
Send ''profibus'' string in PROFIBUS output data area
Module Byte
Data
type
Representation
Value
Description
Output 0
Byte
Hex
0x01
Operation mode
Output 1
Byte
Hex
0x00
→
0x01
Trigger byte
Output 2
Byte
Hex
0x00
Output 3
Byte
Hex
0x09
Connection ID
Output 4
Word
Hex
0x00
Output 6
Word
Hex
0x0A
Total length of message
Output 8
Byte
Hex
0x01
Total numbers of Index
Output 9
Byte
Hex
0x00
Current Index
System
module
Output 10
Byte
Hex
0x0A
The length of current
message
Output 20
Byte
Hex
0x70
‘p’
Output 21
Byte
Hex
0x72
‘r’
Output 22
Byte
Hex
0x6F
‘o’
Output 23
Byte
Hex
0x66
‘f’
Output 24
Byte
Hex
0x69
‘I’
Output 25
Byte
Hex
0x62
‘b’
Output 26
Byte
Hex
0x75
‘u’
Output module
Output 27
Byte
Hex
0x73
‘s’
At the meantime, TCPserver will response 10 Bytes data “0x00~0x09”.
PROFIBUS master can receive data in the input data area, as shown in the
below: