Page
34 of 52
King Pigeon Communication Co., Ltd.
www.iot-solution.com
Wireless Data Acquisition System - LoRa Gateway BL280
10 Appendix A SMS Command List
Change Pasword
Action
Command
Return Message
Set
Old password
+
P
+
new password
This is new password.
Please save it.
Note: default password is 1234 and new password must be 4 digits
Set Device ID
Action
Command
Return Message
Set
PIDxx
ID
:
xx
Inquire
PIDE
Note: ID is fixed character, range: 1-247, default is 1
Set Device Time
Action
Command
Return Message
Set
PDxxxxxxTyyyy
xxxxxxxxxxxx (year,
month, date, hour,
minute)
Inquire
PD
Note: xxxxxx is year month date and yyyy is hour minute. Each property has 2 bits. If it’s 1 bit,
then add 0 in the front. For example, set device time to be 12:30, Oct 8, 2016, the command
is 1234D161008T1230
Inquire Device Status
Action
Command
Return Message
Inquire
PEE
Time:
Device ID:
IMEI:
Cellular Network
Signal Strength:
External Power Supply
Normal/Power Lost
Model Number:
Version:
Description:
Set Network Priority
Action
Command
Return Message
Set
PNET
Network Priority:
Inquire
PNET+x
Note: x is 0-2, 0 is Ethernet first, 1 is cellular first, 2 is both Ethernet and cellular network. For
example, set Ethernet first, the command is 1234NET0
Set Cellular Network Parameter
Action
Command
Return Message
Set
PAP+Access Point+#+User
Name+#+Password
APN:
User Name:
Password
Inquire
PAP