background image

code R30045.110en                                                                                                                                                                           www.kseniasecurity.com
ed.06/2022

CONFIGURATION

The software configuration supplied by Ksenia is required.

Keypad programming instructions

Open <BUS peripherals -> User interfaces -> ergo-X> menu, if correctly installed, ergo-X will show its serial 

number so it can be added in the system configuration by clicking on icon 

 and then wait for the 

green icon 

as positive feedback. To finish, fill in the optional fields and the numeric keys to run the 

scenarios, save and apply configuration. 
The contextual help describes whatever here is omitted. For all the details, please consult the “lares 4.0 
programming manual”.

Key/mini-Tag programming instructions

Start recognition procedure of user’s key/mini-Tag by clicking “Enroll tags” icon from <System -> Users> 
menu, then select “ergo-X” device and click on <START> button. Put the tag close to the ergo-X RFID area 
and wait for a few seconds until you’ll see the number code displayed; at this point, select a name from the 
Users list and click on STOP button to end the procedure. Repeat the procedure for each user with a key/
mini-Tag.

Led RGB programming instructions

In addition to the standard arming color (red, green, blue) of the RGB LED, to display the arming status of the 
system, it is possible to recognize when one or more specific partitions associated with the keypad are 
armed, thanks to a further customization of fuchsia, white and cyan led colors.
Open <BUS peripherals -> User interfaces -> ergo-X> menu, there are three fields, one for each led color 
(

e.g.: “Partitions associated with Fuchsia color”

), program each field by choosing some partitions among 

those to which the keypad belongs.

In our example

 the keypad led will turn fuchsia when the armed partitions are exactly the ones customized 

in this field. 
If they do not match, the configuration of the "

Partition associated with White color

" field will be checked 

and then the one of "

Partition associated with Cyan color

". 

Again, if there is no match, then the led takes one of the standard colors (red, green, blue) according to the 
arming status.

Scenarios/events programming instructions

To enable the user to arm the system by pressing <1> on ergo-X, for example, the installer must program: 
the "Keypad" event with “Key 1” subtype and associated with the "Arming Mode" scenario.
From <System -> Scenarios> menu you can program any scenario and from <System -> Events> menu the 
identities (keypad, users, zones, outputs, etc.) that generate the event to run the scenario. 

Summary of Contents for ergo-X KSI2100031.302

Page 1: ...hout PIN Scenarios and colors of RGB led associated can be remotely customizable from Installer App ergo X keypad has two I O terminals that can be programmed as inputs with EOL resistors or as Open C...

Page 2: ...rity com ed 06 2022 PRODUCT DESCRIPTION ergo X keypad Mount adapter plate RGB LED Numerical keys 0 9 and key X mini Tag RFID Area Support hooks Holes for wall mounting with flat head screws holes dist...

Page 3: ...FF indicates that the system cannot be armed due to some zones in alarm Led can turn ON when you exclude those zones RFID Area The keypad has an antenna on board with which recognizes the user s key m...

Page 4: ...1 ergo X keypad 2m unshielded cable 8x0 22 1 mounting adapter plate 1 adapter plate locking screw 2 wall plugs and screws 1 adhesive mounting template size 1 1 BUS and Terminals I O cabling The exampl...

Page 5: ...the 8x0 22mm unshielded cable Characteristics of the two terminals are Input Programmable zones connection to the ground terminal or Output Open Collector at 500mA each connection to the positive term...

Page 6: ...wall place the bracket on the dotted box and drill two holes in correspondence with the X indicated by the arrows see image below 2 bring the back of the keypad close to the bracket making it match u...

Page 7: ...dition to the standard arming color red green blue of the RGB LED to display the arming status of the system it is possible to recognize when one or more specific partitions associated with the keypad...

Page 8: ...d M2 are integrated inside the ergo X they can be programmed as inputs from System Zones menu or as outputs from System Outputs The contextual help for the page describes whatever here is omitted For...

Page 9: ...f when the timer expires Without PIN 0 9 Hold down the programmed key and wait for 3 seconds to execute the scenario desired The RGB led will take the same color as the programmed scenario if it chang...

Page 10: ...ccording to local provisions Correct disposal of this product guarantees it undergoes the necessary treatment recovery and recycling This prevents any potential negative effects on both the environmen...

Reviews: