background image

© 2016 Spectrum Brands, Inc. 

The door lock will only retain valid user code types (0x01, 0x03, and 0x04).  All other 
values will be ignored.  If a user code does not exist for the corresponding configuration 
parameter, the lock will report a value of 0xFF.  Any attempts to change the user code for 
a non-existent user will be ignored. 

A user code can only be set to one user code type at a time and, as indicated in the table 
above, user code types are associated with Schedule Entry Lock CC schedule types. This 
association between user code type and entry schedule type correlates to the Schedule 
Entry CC specification in that only one schedule type (week day or year day) may be 
associated with a user code at any time. Note: This does not prohibit a user code from 
having multiple schedules of the same type (Year Day or Week Day). 

By default all user codes are assigned type “Owner” when created. The type “Owner” 
designation indicates that that user code is active at all times. When an entry schedule is 
created for a user code, the associated user code type will automatically change 
depending on the type of schedule created. Example: If a weekday schedule is created for 
a user code the associated user code type will change to “Worker”. If a year day schedule 
is created for a user code the associated user code type will change to “Guest”. 

If a user code is of type “Worker” or “Guest” it must have an enabled entry schedule to 
have access to the lock. If a user code of type “Worker” or “Guest” does not have an 
enabled schedule or if there are no entry schedules defined the associated user code will 
not be given access by the lock. 

To provide the user code access to the lock the system must perform one of three actions: 

Re-enable the entry schedule for the user code that was previously disabled 

Create a new entry schedule for the user code 

Change the user code type to “Owner” 

WARNING

: If a user code is of type “Worker” or “Guest” and the system changes the 

user code type to “Owner” the associated user code will be given access to the lock 24/7 
regardless of any entry schedules defined for the user in the lock. 

2.2  Configuration Parameter 31 

Configuration parameter is a one byte read only bit mask that returns the state of the user 
accessible dipswitches on the rear panel of the door lock. 

The following table shows the definition for the bits being used in the returned value: 

Summary of Contents for Smartcode 914

Page 1: ...hich latch are you installing YES NO Use latch A If the latch bolt is not already extended extend the latch bolt as shown wood block actual size Use latch B not included If the latch bolt is not already extended extend the latch bolt as shown Latch A Latch B S 2x C Q 2x Longer screws install closest to the door jamb door frame E Install strike on the door frame Make sure the hole in the door frame...

Page 2: ...into bottom hole Insert key and test latch If latch does not extend or retract smoothly adjust screws T Remove key when finished and make sure the latch bolt is fully extended Keep parallel to edge of door Tighten screws evenly a a c c b b d d Make sure turnpiece is in the vertical position Door handing process was successful Proceed to next step after latch bolt stops moving Remove battery pack w...

Page 3: ... Enter user code A total of 30 user codes may be programmed Press Lock button once A B C What lights and sounds does the lock produce D Each user code must be a unique code between 4 and 8 digits depending on your smart home system Programming was successful Programming was unsuccessful Make sure not to pause for more than 5 seconds during programming Make sure the user code is not a duplicate and...

Page 4: ...ve System Notes This product is a security enabled Z wave Plus product and must be used with a Security Enabled Z Wave controller to be fully utilized Z Wave is a Wireless mesh network and results may vary based on building construction and communication path To assure interoperability each Z Wave product must pass a stringent conformance test to assure that it meets the Z Wave standard for comple...

Page 5: ...s 2 Configuration Parameters The Z Wave door lock module supports the use of the configuration command class to provide advanced configuration of the door lock over the Z Wave network This section describes the configuration parameters supported by the door lock 2 1 Configuration Parameters 1 through 30 Configuration parameters 1 through 30 are a one byte field used to set the type of user for the...

Page 6: ... on the type of schedule created Example If a weekday schedule is created for a user code the associated user code type will change to Worker If a year day schedule is created for a user code the associated user code type will change to Guest If a user code is of type Worker or Guest it must have an enabled entry schedule to have access to the lock If a user code of type Worker or Guest does not h...

Page 7: ...rogram the first four bytes of the SKU Setting parameter 34 will program the last 4 bytes of the SKU Most printable values are accepted for the set command When getting the SKU it must be done in two get commands one for each parameter The order of getting the SKU does not matter Getting parameter 33 will retrieve the first four bytes of the SKU Getting parameter 34 will retrieve the last 4 bytes ...

Page 8: ...k and will remove it from your smart home system It will not remove any anti theft settings Please use the local reset procedure only when the primary controller is missing or inoperable 5 1 Local 1 Remove battery pack and press the program button a few times to discharge 2 Press and hold the program button 3 Replace the battery pack 4 Continue holding the program button for 30 seconds until the l...