Page 21 / 23
Need to click the button after input the value.
- Inc. Auto: Gradually increase the output power of laser to 100%
User can input the value from 0 to 255 user want in the box of ‘Auto Spd:
- Dec. Auto: Gradually decrease the output power of laser to 0%
User can input the value from 0 to 255 user want in the box of ‘Auto Spd:
- Stop: Stop the changing output power when the laser power are changing by command of ‘Inc. Auto’ or ‘Dec.
Auto’
5.4 Motor Command
Command group to which the beam angle control
- MIN: Move to the minimum step position
- Dec NN: Move the 250 step to minimum step position
- MID: Move to the middle step position
- Inc NN: Move the 250 step to maximum step position
- MAX: Move the maximum step position
- Dec N: Move the 25 step to minimum step position
- Inc N: Move the 25 step to maximum step position
- Pos: Move any position
User can set the step position value if user input the value in the box of Position or use slider control bar.
Control automatically the step range as the choice of target product. (ex: VM-P6000=4500, VM-
S200=3300)
- Spd: Move to any position
User can set the speed value from 0 to 255 if use input the value in the box of Pos&Auto Speed
5.5 FAN Command
Command group to which the heat sinking fan control