LucidControl DI4DO4, User Manual (1.0)
2022/02/03
Page 30 of 47
3.3.4
GetIoGroup
This command reads the input or output values of a group of IO of the same Value Type.
Tab. 6 lists the digital output channel modes and how the IO value is interpreted.
Tab. 8 lists the digital input channel modes and how the IO value is interpreted.
Command
GetIoGroup
Access
Read
Opcode
0x48
LucidIoCtrl Command Line Tool
Call (-tL)
LucidIoCtrl
–
d[COMx]
–
c[Channels]
–
tL
–
r
Channels
Comma separated list of channels e.g.
–
c0,1,7
Return
List of values sorted from lower to higher channels
CHn:L
n
Channel
L
Digital Value
Call (-tN)
LucidIoCtrl
–
d[COMx]
–
c[Channels]
–
tN
–
r
Return
CHn:V
n
Input Channel
V
Input Count Value
LucidIoCtrl Command Line Tool Example
Read digital input channels 0, 1 and digital output channel 7.
LucidIoCtrl
–
dCOM4
–
c0,1,7
–
tL
–
r [ENTER]
CH0:00 CH1:01 CH7:01
Request Frame
OPC
P1
P2
LEN
0x48
Channel
Mask
Value Type
0