29 27
5. Commands, cont.
New Mondo III Matrix Reporting & Configuration Commands:
$RFD - Report fan/filter data (M3)
Report fan / filter data, all frames:
Command: $RFD
<CR>
(One line for each frame)
Response: frame,a,b,c,d,e
<LF><CR>
frame,a,b,c,d,e
<LF><CR>
OK>
<LF><CR>
Report fan / filter data, one frame:
Command: $RFDframe
<CR>
Response:
frame,a,b,c,d,e
<LF><CR>
OK>
<LF><CR>
frame = frame address 0..159
a =
Fan-1 status code
b =
Fan-1 RPM
c =
Fan-2 status code
d =
Fan-2 RPM
e =
Filter status code
Fan status codes:
0 = fan operation normal
1 = locked rotor, or complete fan failure detected.
2 = fan speed unusually slow (bearing failure?)
3 = fan speed unusually fast (air filter dirty?)
Air filter status codes:
0 = filter OK.
1 = not implemented.
2 = filter needs changing now.
3 = not implemented.
The response is always in groups of 5 fields, with a comma as the delimiter. One group for every active
frame in the system.
$FSI – Filter Service Interval, all frames (M3)
Read days remaining, all frames :
Command: $FSI
<CR>
(One line for each frame)
Response:
frame,n
<LF><CR>
frame,n
<LF><CR>
OK>
<LF><CR>
Set filter service interval:
Command: $FSIframe,n
<CR>
Response:
OK>
<LF><CR>
frame = frame address 0..159, Use * for setting filter service interval on all frames at once.
n =
Days until next filter-service interval. If read as “0” filter must be serviced immediately. By
setting a new interval, it resets the day-countdown clock too.
Note:
to disable the filter service warning / alarm, set the service interval to “255”.
Summary of Contents for Mondo III Matrix
Page 1: ...1 Mondo III Matrix Installation Setup Guide...
Page 43: ...43 41 NOTES...