Figure 4-2. Physical Calibration Parameters Received with PHY Calibration Tool
4.2
PRIME Projects
The PHY Calibration Tool generates the report file “
atpl360_coup_cfg_PRIME.h
“ which contains the
custom values that must be included on PRIME projects. The process must be done for each channel in
use.
shows the correspondence between report file and application code.
Table 4-1. Correspondence for PHY Calibration Tool File Report
MAX_RMS_HI_TABLE
static const uint32_t spul_max_rms_hi
MAX_RMS_VLO_TABLE
static const uint32_t spul_max_rms_vlo
TH1_HI_TABLE
Not in use
TH2_HI_TABLE
static const uint32_t spul_th_hi
TH1_VLO_TABLE
Not in use
TH2_VLO_TABLE
static const uint32_t spul_th_vlo
PREDIST_COEF_HI_TABLE
static const uint16_t spus_equ_hi_BAND
PREDIST_COEF_VLO_TABLE
static const uint16_t spus_equ_vlo_BAND
PL360
How to Use Calibration Values
©
2018 Microchip Technology Inc.
User Guide
DS50002818A-page 12