Messages
CMP DATA ERROR FIELD
Section 5.2, Error Handling on Page 44.
UPDATE DATA NOT COMPLETE AT 1PPS FIELD
If a ‘1’, this flag indicates that a command received during the previous 1 second epoch was incomplete.
STATUS DATA NOT COMPLETE AT 1PPS FIELD
If a ‘1’, this flag indicates that a status message was not transmitted completely during the previous 1-second epoch.
This flag is reset after the status message has been transmitted.
PARITY ERROR ON RECEIVED DATA FIELD
If a ‘1’, this flag indicates that the UART detected a parity error in one or more command bytes during the previous
1-second epoch. This flag is reset after the status message has been transmitted.
FRAMING ERROR ON RECEIVED DATA FIELD
If a ‘1’, this flag indicates that the UART detected a framing error in one or more command bytes during the
previous 1-second epoch. This flag is reset after the status message has been transmitted.
OVERRUN ERROR ON RECEIVED DATA FIELD
If a ‘1’, this flag indicates that the UART detected an overrun error in one or more command bytes during the
previous 1-second epoch. This flag is reset after the status message has been transmitted.
RECEIVE DATA SYNC ERROR FIELD
If a ‘1’, this flag indicates that the Signal Generator did not receive a valid sync byte in a command packet during
the previous 1-second epoch. This flag is reset after the status message has been transmitted.
RECEIVE DATA CRC ERROR FIELD
If a ‘1’, this flag indicates that the Signal Generator detected an invalid CRC field in a command packet during the
previous 1-second epoch. This flag is reset after the status message has been transmitted.
D4
Framing Error on Received Data
0 = No Error
1 = Error
D5
Overrun Error on Received Data
0 = No Error
1 = Error
D6
Receive Data Sync Error
0 = Valid Sync Byte
1 = No Valid Sync Byte
D7
Receive Data CRC16 Error
0 = Valid CRC Field
1 = No Valid CRC Field
D8
Invalid Field Value in Last Command Received
0 = Valid Field Value
1 = Invalid Field Value
D9
Invalid Range Fields
0 = Valid Range Fields
1 = Invalid Range Fields
D10-D15
Reserved for future use. Set to zero.
Bit
Error Status Description
Range