System Programming
TIE Wink Time Out Assignment
436
48
Description
The TIE outgoing method can be set to the wink mode in program
[433] “TIE Outgoing Assignment”. This program sets the time the
system waits for the confirmation wink signal after a CO line is
seized according to your central office service. The system
disconnects the CO line when the time-out expires.
Selection
• TIE table number: 1 to 4,
(
=all TIE tables)
• Time: 1 through 127 (
✕
64 milliseconds is the actual time)
Default
All TIE tables – 16
Programming
1.
Enter 436.
Display: TIE Wink Timeout
2.
Press NEXT.
Display: Table NO?
→
3.
Enter a TIE table number.
To enter TIE table number 1, you can also press NEXT.
Display example: 1:16
4.
Enter the time.
To change the current entry, press CLEAR and enter the new number.
5.
Press STORE.
6.
To program another TIE table, press NEXT or PREV, or
SELECT and the desired TIE table number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• You cannot leave the entry empty.
• To assign all TIE tables to one selection, press the
key in step 3. In
this case, the display shows the contents programmed for TIE table
number 1.
Summary of Contents for KX-TD1232CE