Binary Switch Get Command:

[Command Class Switch Binary, Switch Binary 

Get]

 

Binary Switch Report Command: 
Report OFF:

[Command Class Switch Binary, Switch Binary Report, Value 

=0(0x00)]

 

Report ON:

[Command Class Switch Binary, Switch Binary Report, Value = 

255(0xFF)]

 

 

1-2 BASIC_SET / SWITCH_BINARY_SET 

    Upon  receipt  of  the  following  commands  from  a  Z-Wave  Controller,  the  load 

attached to the Switch will turn on or off. 

 

[Command  Class  Basic,  Basic  Set,  Value  =  1~99,  255(0xFF)]

:  the  load 

attached to the Switch turns on.

 

[Command Class Basic, Basic Set, Value = 0(0x00)]

: the load attached to the 

Switch turns off.

 

[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  1~99, 
(255)0xFF]

: the load attached to the Switch turns on.

 

[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  0(0x00)]

:  the 

load attached to the Switch turns off.

 

 

1. 

Z-

Wave’s Groups (Association Command Class Version 2)

 

 

The  Switch  can  be  set  to  send  reports  to  associated  Z-Wave  devices.    It  supports 

one association group with one node support for Grouping 1. For group 1, the Switch 

will report its latest status to Z-Wave Controller.  
 
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, 
ALARM_REPORT. 
 

2-1 Auto report to Grouping 1 (Maximum Node 1) 

 
2-1-1 On/Off Event Report  

   

When “on” or “off ” state has been changed, it will send Binary Switch Report to the 

node of Grouping 1.  

    
Binary Switch Report 
 

ON:

[Command Class Switch Binary, Switch Binary Report, Value 

=255(0xFF)]

 

OFF:

[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]

 

 

2-1-2 Instant Power Consumption vary over 5% report 

When the power consumption of load vary over 5%, it will send Meter report to the 

nodes of Grouping 1. 
 

Meter Report Command: 

[Command Class Meter

Meter Report

Rate Type 

= 0x01

Meter Type = 0x01

Precision = 1

 Scale = 0x02

 Size = 

4

Meter Value(W)

 

 

 2-1-3 Overload alarm report 

When PAN15 detects the current is more than 14.5A, it will send Alarm Report to 

Group 1 node. 

After detecting overload state and sending this alarm report, PAN15 

will turn off the switch automatically and lockout the On/Off button. The only thing to 

do is unplug PAN15 and reduce the load. Then replug PAN15 and it will work again.

 

The content of Alarm Report  

Alarm report command:

 [Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, 

Alarm Level = 0xFF] 

 
2-2 Response to Meter Get Command 

   The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated 

power consumption(KWH) or (3)

 

AC load Voltage (V) or (4)

 

AC load current ( I ) 

(5)

 

load  power  factor  (PF)  to  Z-Wave  Controller  after  receive  the  Meter  Get 

Command from Z-Wave Controller. 

 

2-2-1 Instant Power Consumption (Watt) of Switch 

    When receiving Meter Get Command, it will report Meter Report Command to the 

node asked. 

 

Meter Get Command: 

[Command Class Meter, Meter Get, Scale =0x02(W)]

 

Summary of Contents for PAN15-1

Page 1: ...oggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a w...

Page 2: ...intervals Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do not l...

Page 3: ... send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consumption of load vary over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter M...

Page 4: ...e 3 256 Meter Value 4 800 35 KW h 2 2 3 Clearing accumulated power consumption Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale ...

Page 5: ...t its instant power consumption every 1 hour to Group1 node The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr 3 2 KWH Meter Report Period If the setting is configured for 1hour set value 6 the PAN15 will report its Accumulated Power Consumption KW h every 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 ...

Page 6: ...otect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN15 is based on 500 series SoC...

Page 7: ... systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Company of License Holder Philio Technology Corporation Address of License Holder 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital d...

Page 8: ...r s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Information Company s Markings Purpose of control Operating electronic appliance control Construction of the control Plug In operating control Type 1 or Type 2 Action Type 1 Operating Time Continuous ...

Reviews: