Network and Remote Operation
R&S
®
FSVA3000/ R&S
®
FSV3000
665
User Manual 1178.8520.02 ─ 01
4. Wait for a service request.
The service request indicates that the overlapped command has finished.
*OPC? with a service request
1. Set bit no. 4 in the SRE:
*SRE 16
to enable MAV service request.
2. Send the overlapped command with
*OPC?
.
3. Wait for a service request.
The service request indicates that the overlapped command has finished.
Event status register (ESE)
1. Set the OPC mask bit (bit no. 0) in the ESE:
*ESE 1
2. Send the overlapped command without
*OPC
,
*OPC?
or
*WAI
.
3. Poll the operation complete state periodically (with a timer) using the sequence:
*OPC; *ESR?
A return value (LSB) of 1 indicates that the overlapped command has finished.
13.1.7
Status Reporting System
The status reporting system stores all information on the current operating state of the
instrument, and on errors which have occurred. This information is stored in the status
registers and in the error queue. Both can be queried via GPIB bus or LAN interface
(
STATus
... commands.
(See
Chapter 14.11, "Using the Status Register"
............................................................................... 665
Structure of a SCPI Status Register
......................................................................667
Contents of the Status Registers
.......................................................................... 668
Application of the Status Reporting System
..........................................................679
Reset Values of the Status Reporting System
...................................................... 681
13.1.7.1
Hierarchy of Status Registers
As shown in the following figure, the status information is of hierarchical structure.