25
Properties
Firmware Version
Get
Set
ID 1
ID 2
Data Bytes
Data
X
7F
01
8
Firmware version:
0: Major
1: Minor
2: Patch
3: Release type (ascii)
4-7: Build number
Returns the firmware version.
Input voltage
Get
Set
ID 1
ID 2
Data Bytes
Data
X
7F
0B
2
100 * PSU voltage in Volts
Returns the approximate input voltage. Can be useful for diagnosing power issues.
MIDI Channel
Get
Set
ID 1
ID 2
Data Bytes
Data
X
X
7F
12
1
00: channel 1 (default)
01: channel 2
...
0F: channel 16
Get or set MIDI channel.
Save preset
Get
Set
ID 1
ID 2
Data Bytes
Data
X
7F
13
1
Preset location (MIDI program number)
Save a preset to internal memory.
Get / Set Parameter Value (high resolution)
Get
Set
ID 1
ID 2
Data Bytes
Data
X
X
yy
yy
1
U1.23 fixed point value encoded as 4
7-bit digits
Uses internal parameter IDs to get and set parameters with high resolution. The property IDs (yyyy) are
not currently documented, but can be found using our web editor and a MIDI monitor. We reserve the
right to change the IDs and data format, so please email us if you plan to use them (or have any ques-
tions). Values are unsigned 1.23 fixed point numbers from 0 to 1, inclusive.