Remote-Control Commands
IEEE 802.11 (a/b/g)
67
Operating Manual 1171.5283.12 ─ 18
Parameters:
<SLength>
float
Range:
1 to (2^32-1) chips
Increment: 1 chip
*RST:
32 768 chips
Example:
BB:WLAN:SEQ SING
sets trigger mode Single.
:BB:WLAN:TRIG:SLEN 200
sets a sequence length of 200 chips. The first 200 chips of the
current frame will be output after the next trigger event.
Manual operation:
See
[:SOURce<hw>]:BB:WLAN:TRIGger:SLUNit
<Slunit>
The command defines the unit for the entry of the length of the signal sequence
(
SOUR:BB:WLAN:TRIG:SLEN
) to be output in the "Single" trigger mode
(
SOUR:BB:WLAN:SEQ SING
).
Parameters:
<Slunit>
FRAMe | CHIP | SEQuence
FRAMe
Unit Frame. A single frame is generated after a trigger event.
CHIP
Unit Chip. A single chip is generated after a trigger event.
SEQuence
Unit Sequence Length. A single sequence is generated after a
trigger event.
*RST:
SEQuence
Example:
BB:WLAN:SEQ SING
sets trigger mode Single.
BB:WLAN:TRIG:SLUN FRAM
sets unit Frame for the entry of sequence length.
BB:WLAN:TRIG:SLEN 2
sets a sequence length of 2 frame. Two frames will be output
after the next trigger event.
Manual operation:
See
[:SOURce<hw>]:BB:WLAN:TRIGger:SOURce
<Source>
Selects the trigger source.
Parameters:
<Source>
INTernal|OBASeband|BEXTernal|EXTernal
INTernal
manual trigger or
*TRG
.
EXTernal|BEXTernal
Trigger Settings