Controller functions
Page 36
UPT-606
9.8.3
DPV1 parameter data
The basic controller settings and functions can be set
with the parameter data in the device master file (GSD
file,
section 9.7 "Parameter data" on page 30).
Some PLC systems only allow you to change the set-
tings in the GSD file when you create a new project.
The settings cannot be changed while the machine or
system is operating.
The DPV1 protocol extension makes it possible to
change these settings and functions without interrup-
ting the operation of the controller. The temperature
coefficient for the heating elements, for instance, can
be altered on the PLC control unit during the validation
process.
This acyclic service supports both reading and writing
of the controller parameters. The parameter data can
optionally be accessed by addressing the slot indexes.
Since the controller does not store parameters trans-
ferred to it in this way, you must remember to transfer
all parameters that deviate from the static configuration
again after restarting the controller or the bus.
Please contact the manufacturer for more
information about how your PLC system sup-
ports the DPV1 protocol extension.
DPV1 parameter table of the UPT-606
Default values are printed
bold/cursive
.
!
Slot
Index
Parameter
Value range
x
255
I&M functions (IM0)
Article number, serial number,
version index, manufacturer ID
0
0
Cyclic data
section 9.4 "PROFIBUS protocol"
on page 23
1
4
Alloy/range
0: 1100ppm/K, 300°C
1: 780ppm/K, 300°C
4: 1100ppm/K, 500°C
5: 780ppm/K, 500°C
8: 3500ppm/K, 300°C
9: PC configuration
10: Rotary coding switch
11: variable
1
5
Lower temperature limit [K]
3…99
(
10
)
1
6
Upper temperature limit [K]
3…99
(
10
)
1
7
Calibration temperature [°C]
-1: variable with cyclic data
0…40
(
20
)
1
8
Heating time limit [0.1s steps]
0…99
(
0=without limit
)
1
9
Extended controller diagnosis
0: deactivated
1: activated
1
10
Measuring pulse length [0.1ms steps]
17…30
(
17
)
1
11
Data format
0: Intel
1: Motorola
1
12
Correction factor Co [%]
25…200
(
100
)
1
13
Maximum starting temperature [°C]
20…500
(
100
)
1
15
Error code format
0: 4 bit (2 digits)
1: 10 bit (4 digits)