42
DLE DC4 fn m t
(fn=1)
[Name]
[Format]
[Range]
[Description]
Generate pulse in real-time.
ASCII DLE
DC4 fn m t
Hex 10
14
1
m
t
Decimal 16 20 1 m t
fn=1
0
≤
m
≤
8
1
≤
t
≤
8
▪
Outputs the pulse specified by t in real-time to the connector pin specified
by m as follows :
n Connector
pin
0
Drawer kick-out connector pin 2.
1
Drawer kick-out connector pin 5.
- The pulse ON time or OFF time is set to [t x 100 ms].
▪
Specify n=1 or 2 after removing the cause of the error.
▪
If print data includes a character string with this command, the printer
performs the command. User must consider this.
- For example : Bit image data accidentally might include a data string
with this command.
▪
Do not embed this command within another command.
- For example : Bit image data might include this command.
▪
This command is ignored in the following states :
- During transmission of block data.
- During driving of drawer kick-out.
- When an error has occurred.
DLE DC4 fn a b
(fn=2)
[Name]
[Format]
[Range]
[Description]
Execute power-off sequence.
ASCII DLE
DC4 fn a b
Hex 10
14
fn
a b
Decimal 16 20 fn a
b
fn=2
a=1
b=8
▪
Executes the printer power-off sequence.
- Stores the values of the maintenance counter.
- Transmits the following power-off status ( NUL).
Power off status
Hex
Decimal
Amount of data
Header
3B H
59
1 byte
Status
30 H
48
1 byte
NUL
00 H
0
1 byte
43
[Notes]
- Executes the printer power off.
▪
If this command is encountered, the printer will not continue to process
anything. To recover the printer to print again, it is necessary to turn the
power on again or execute a hardware reset.
▪
If print data includes a character string with this command, the printer
performs the command. User must consider this.
- For example : Bit image data accidentally might include a data string
with this command.
▪
Do not embed this command within another command.
- For example : Bit image data might include this command.
▪
This command is ignored block data is transmitted.
DLE DC4 fn d1...d7
(fn=8)
[Name]
[Format]
[Range]
[Description]
Clear buffer(s).
ASCII DLE
DC4 fn
d1...d7
Hex 10
14
8
d1...d7
Decimal 16 20 8 d1...d7
fn=8
d1=1, d2=3, d3=20, d4=1, d5=6, d6=2, d7=8
▪
Clear all data stored in the receive buffer and the print buffer.
▪
Transmits the following three bytes data.
Hex
Decimal
Amount of data
Header
37 H
55
1 byte
Flag
25 H
37
1 byte
NUL
00 H
0
1 byte
[Notes]
▪
Enters standard mode.
▪
The command must be inhibited for use in a system using this printer and
the EPSON OPOS.
▪
If print data includes a character string with this command, the printer
performs the command. User must consider this.
- For example : Bit image data accidentally might include a data string
with this command.
▪
Do not embed this command within another command.
- For example : Bit image data might include this command.
▪
This command is ignored block data is transmitted.
ESC FF
[Name]
[Format]
[Description]
Print data in page mode.
ASCII ESC FF
Hex 1B
0C
Decimal 27 12
▪
In page mode, prints all buffered data in the printing area collectively.
Summary of Contents for 2 COLOR THERMAL PRINTER SRP-370
Page 11: ...20 Page 1 Katakana 21 Page 2 PC850 Multilingual ...
Page 12: ...22 Page 3 PC860 Portuguese 23 Page 4 PC 863 Canadian French ...
Page 13: ...24 Page 5 PC 865 Nordic 25 Page 16 WPC1252 Latin 1 ...
Page 14: ...26 Page 17 PC866 Cyrillic 2 27 Page 18 PC852 Latin2 ...
Page 15: ...28 Page 19 PC858 Euro 29 Page 22 PC864 Arabic ...
Page 16: ...30 Page 23 Thai character code 42 31 Page 24 WPC1253 Greek ...
Page 17: ...32 Page 28 WPC1251 Cyrillic 33 Page 29 PC737 Greek ...
Page 18: ...34 Page 255 Space Page 35 International Character Set ...