PLC-XU305A/355A Expand Serial Command Functional Specifications
63/68
9.11.19 CR_KEYDIS Command
Command “CR_KEYDIS”(CR)
Details
Get disability status of RC/Projector keys (valid or invalid)
Response
Acceptable
“000_%a”[CR]
%a
“NONE” -------------------------- RC / Projector keys are valid
“RC” ------------------------------ RC keys are invalid
“KEY” ----------------------------- Projector keys are invalid
Unacceptable “Error Code” [CR]
9.11.20 CR_PJLOCKNOW Command
Command “CR_PJLOCKNOW” [CR]
Details
Get if PJ lock is actually in operation
Response
Acceptable
“000_%1[CR]
%1
“LOCK” ------------- PJ Lock is in operation. PJ Lock status is ON-1
or ON-2 on Menu, and PJ PIN CODE is not
entered so that projector is actually locked.
“FREE” ------------- PJ Lock is released. PJ Lock status is OFF, or,
status is ON-1 or ON-2 on Menu but PJ PIN
CODE is entered correctly so that PJ Lock is
released.
Unacceptable “Error Code” [CR]
9.11.21
CR_PJLOCKMENU Command
Command “CR_PJLOCKMENU” [CR]
Details
Get status of PJ Lock on Menu
Response
Acceptable
“000_%1[CR]
%1
“ON1” ------------- PJ Lock status is On-1
“ON2” ------------- PJ Lock status is On-2
“OFF” ------------- PJ Lock status is OFF
Unacceptable “Error Code” [CR]
9.11.22 CR_FANMODE Command
Command “CR_FANMODE”[CR]
Details
Get selected Fan mode
Response
Acceptable
“000_%a”[CR]
%a
“L1” ----------------------- Fan mode is L1
“L2” ----------------------- Fan mode is L2
Unacceptable “Error Code” [CR]
9.11.23 CR_FANCONTROL Command
Command “CR_FANCONTROL”[CR]
Details
Get selected Fan control setting status
Response
Acceptable
“000_%a”[CR]
%a
“OFF” ----------------------- Fan control is OFF
“ON1” ----------------------- Fan control is ON1
“ON2” ----------------------- Fan control is ON2
“ON3” ----------------------- Fan control is ON3
Unacceptable “Error Code” [CR]