PNU
FUNCTION
PARAMETER
24
Protection active / reset
If read
= 0x00
drive ready
= 0x02
short circuit
= 0x04
thermal protection
= 0x08
power supply
undervoltage
= 0x10
power supply
overvoltage
(in previous profibus versions in case of
protection this value is set to 1)
If write 0 reset permanent protection (short
circuit or phase disconnected) the other
protections are automatically resetted when
the error condition disappear
25
Software release
READ ONLY REGISTER
26
Power supply voltage [Vdc]
READ ONLY REGISTER
27
Drive temperature [°C]
READ ONLY REGISTER
50
Encoder position
Encoder position register, you can read or write this value. (expressed in encoder
steps)
This value counts all fronts of two encoder phases
From -2147483647 to 2147483647
51
Encoder mode
Set encoder mode
If Write 0
no encoder feedback.
You can read encoder
but the drive don’t
use it to control position
1
encoder enabled
without error detection
2
encoder enabled with
error detection
52
Set encoder pulse/revolution
From 0 to 2147483647
53
Set encoder fault steps
Set encoder steps to detect positioning error.
From 0 to 2147483647
54
Encoder Index search frequency
It defines the search index frequency
From 1 to 5000 Hz
55
Encoder index search mode
Indicate 4 modes to search index
0x01= search CW
0x02= search CCW
0x11= search CW and set position to 0
0x12= search CCW and set position to 0
26
www.shsitalia.it info:shsbox@shsitalia.it
Summary of Contents for EtherCAT HT7
Page 76: ...www shsitalia it info shsbox shsitalia it 15 ...
Page 91: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Page 92: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Page 95: ...www shsitalia it info shsbox shsitalia it 18 ...
Page 110: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Page 111: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Page 124: ...www shsitalia it info shsbox shsitalia it 28 ...