SCAN_PROP_ID_RING_UNIT_BUILD_ID
Purpose: Contains the ring unit build version.
Value type: DWORD.
Operation available: Read Only.
SCAN_PROP_ID_PERMANENT_PAIR
Purpose: Flag to activate the permanent pair.
Value type: DWORD.
Operation available: Read Write and Updateable.
SCAN_PROP_ID_BATTERY_LEVEL
Purpose: Contains the battery level.
Value type: DWORD.
Operation available: Read Only.
SCAN_PROP_ID_ENABLE_CORDLESS
Purpose: Flag to activate or desactivate the cordless scanner support.
Value type: DWORD.
Operation available: Read Write.
SCAN_PROP_ID_LOCKOUT_TIMER
Purpose: Trigger lockout timer.
Value type: DWORD.
Operation available: Read Write and updateable.
SCAN_PROP_ID_ADVANCED_BEEP_FREQ
Purpose: defines the advanced beep frequency.
Value type: DWORD.
Operation available: Read Write and updateable.
SCAN_PROP_ID_ADVANCED_FLASH
Purpose: flag to activate or desactivate the advanced flash.
Value type: DWORD.
Operation available: Read Write and Updateable.
SCAN_PROP_ID_ADVANCED_BEEP
Purpose: flag to activate or desactivate the advanced beep.
Value type: DWORD.
Operation available: Read Write and Updateable.
SCAN_PROP_ID_BEEPER_FREQ
Purpose: define the frequency for the good read beep.
Value type: DWORD.
Operation available: Read Write and Updateable.
April 8, 2010
Page 55
Document#: 6410-00147 K
Revision 2.28