Examples

Description

Example Code

Turn on flood coolant, maintain stream at Z0

M08

Turn on flood coolant, maintain stream at 1 unit above Z0

M08 E1

Turn on flood coolant, aim stream at tool tip

M08 P0

Turn on flood coolant, aim stream at 1 unit above tool tip

M08 P1

Turn on flood coolant, aim stream at 3 units below tool tip

M08 P-3

Turn on flood coolant, aim stream at tool tip and oscillate between tool tip and 3 units above tool tip

M08 P0 R3

Turn on flood coolant, maintain stream at Z0 and oscillate between Z0 and 3 units above Z0

M08 R3

Turn on mist coolant or air, aim stream at Z0 

M07

Turn off all coolant

M09

Keyboard Shortcuts

Key Code Description

Alt + U

Manually override PathPilot coolant control to point nozzle up

1

Alt + D

Manually override PathPilot coolant control to point nozzle down

1

Alt + C

Cancel manual override of PathPilot coolant control; reverts to automatic control

Alt + M

Toggle auxiliary solenoid on and off (requires SmartCool MultiCoolant Module, PN 37168)

1

Cancel manual override with Alt + C or any subsequent M-code command.

ADMIN Commands

The aiming of the SmartCool Head Unit can be fine-tuned to compensate for installation variance or a sagging 

coolant stream (non-linear).

ADMIN Command

Description

ADMIN SMARTCOOL_OFFSET

Offset SmartCool Head Unit up or down as appropriate. Positive values move the 

stream up, negative values move the stream down.

For example, 

ADMIN SMARTCOOL_OFFSET 1.0

 moves the coolant stream one unit higher.

NOTE: 

This offset applies to every pointing operation, and is retained by the controller; it is not affected by 

PathPilot software upgrades.

Summary of Contents for SmartCool

Page 1: ...oolant Module PN 37168 4 Relocate Flood Coolant Mounting Bracket 9 Programming 5 Make Coolant Connections 10 Troubleshooting Qty SmartCool Starter Kit PN 1 SmartCool Head Unit 1 Control Module 1 USB C...

Page 2: ...ant 440 Relocation Bracket IMPORTANT Download and install the latest version of PathPilot before proceeding PathPilot v1 9 7 or later is required to use these instructions For more information refer t...

Page 3: ...tCool Head Unit roughly in center of slots on Mounting Bracket see Figure 4 Final adjustments will be made after installation is complete to ensure coolant stream is correctly positioned 4 Using two M...

Page 4: ...and B as shown in Figure 8 4 Route control cable from SmartCool Head Unit to back of mill based your specific mill configuration If power drawbar optional is installed Route through power drawbar s ca...

Page 5: ...es as shown in Figure 11 and Figure 12 2 Slowly run spindle head up and down to ensure control cable cannot get caught in any part of mill Relocate Flood Coolant Mounting Bracket If your mill is equip...

Page 6: ...uire one hole to be drilled and tapped behind SmartCool s Mounting Bracket Temporarily place Relocation Bracket on spindle column flush with right edge of spindle head casting as shown in Figure 15 ma...

Page 7: ...are pre configured for use with flood coolant but can be configured to use mist coolant as the primary coolant source NOTE An optional MultiCoolant Module PN 37168 allows the SmartCool to use flood co...

Page 8: ...igure 20 and set aside 3 Remove Hub s mounting plate from front of SmartCool Head Unit see Figure 21 identify two slots for flood and mist coolant Hub mounting plate follows same pattern as hub cap 4...

Page 9: ...e Figure 23 NOTE If equipped with optional MultiCoolant Module PN 37168 wait to make M07 Auxiliary Solenoid connection until SmartCool MultiCoolant Module section later in this document 2 Control Modu...

Page 10: ...ype M8 P0 to turn on flood coolant and aim stream at tip of tool for more information refer to Programming Guide section later in this document 3 Observe coolant stream if necessary adjust SmartCool H...

Page 11: ...aims the top slot of the hub Typical system configurations are Flood M08 and air M07 Flood M08 and Fog Buster M07 Fog Buster M08 and air M07 Installation 1 Determine your primary and secondary coolant...

Page 12: ...the Fog Buster through the SmartCool s Control Module 1 Unplug Fog Buster 2 Remove solenoid and power cord from Fog Buster see Figure 29 and set aside keep for future use 3 Remove auxiliary solenoid f...

Page 13: ...ptional if the P word is omitted the target point of the coolant stream is the Z0 R Enables oscillating coolant stream wiggle mode Q Enables pulsing of M07 or M08 solenoid in seconds Requires SmartCoo...

Page 14: ...ff all coolant M09 Keyboard Shortcuts Key Code Description Alt U Manually override PathPilot coolant control to point nozzle up1 Alt D Manually override PathPilot coolant control to point nozzle down1...

Page 15: ...to place If pins do not hold replace control cable Over tightened hub High Listen for a sound from the SmartCool Head Unit that indicates it is working Verify that the SmartCool Head Unit does not mov...

Reviews: