MSR110D Programmer’s Manual UDN PM008 Rev. D
Section 4 – Commands and Responses 2002/3/19
Page
16
Uniform Industrial Corp.
Proprietary and Confidential
Total 44 pages
^ (5Eh)
―
―
―
―
ACK
Comments
Last command has been completed without an error condition, and ready for the next command.
+ (2Bh)
―
―
―
―
No Data
Comments
If host gets the response from reader, it may mean one of following:
1 In case of a "standard format" read command, this response "+" means "no start sentinel (SS) found".
2 In case of a "read error" command, this response "+" means "no history of a previous read error".
* (2Ah)
―
―
―
―
Error
Comments
If host gets the response from reader, it may mean one of following:
1 No end sentinel (ES).
2 Parity error.
3 LRC error.
? (3Fh)
―
―
―
―
Communication Error
Comments
If host gets the response from reader, it may mean one of following:
1 Bad parity.
2 Wrong BCC.
3 Receive character time-out.
4 Message more than maximum character allowed.
! (21h)
―
―
―
―
Invalid Command
Comments
Command issued by the host was not recognized or won’t accept.
: (3Ah)
―
―
―
―
Power On Report
Comments
The interface has completed its initialization cycle.
~ (7Eh)
―
―
―
―
Cannot Execute
Comments
Read or encode command cannot be executed due to lack of hardware in the device.