09h 00h 03h 4Ah 48h 45h 4Dh With
p1
data
(70h 31h
data
)
-
-
-
-
Set Track 1 Prefix Code
1 Prefix can be set as 1-6 characters
2 If first character = 00h, prefix code of track 1 will not be send. It means this function is disabling.
Table 5-13. Set Track 1 Prefix Code
Command Form (Hex)
Track 1 Prefix Code
09h 00h 03h 70h 31h 00h 4Bh
Disable (default)
Example of Track 1 Prefix Code Setting
09h 00h 00h 70h 31h 0Ah 42h
One character: 0Ah
09h 00h 05h 70h 31h 54h 4Bh 01h 53h Five characters: 70h 31h 54h 4Bh 01h 53h
p2
data
(70h 32h
data
)
-
-
-
-
Set Track 2 Prefix Code
1 Prefix can be set as 1-6 characters
2 If first character = 00h, prefix code of track 2 will not be send. It means this function is disabling.
Table 5-14. Set Track 2 Prefix Code
Command Form (Hex)
Track 2 Prefix Code
09h 00h 03h 70h 32h 00h 48h
Disable (default)
Example of Track 2 Prefix Code Setting
09h 00h 00h 70h 32h 0Bh 40h
One character: 0Bh
09h 00h 05h 70h 32h 54h 4Bh 02h 53h Five characters: 70h 32h 54h 4Bh 02h
p3
data
(70h 33h
data
)
-
-
-
-
Set Track 3 Prefix Code
1 Prefix can be set as 1-6 characters
2 If first character = 00h, prefix code of track 3 will not be send. It means this function is disabling.
Table 5-15. Set Track 3 Prefix Code
Command Form (Hex)
Track 3 Prefix Code
09h 00h 03h 70h 33h 00h 49h
Disable (default)
Example of Track 3 Prefix Code Setting
09h 00h 00h 70h 33h 0Ch 46h
One character: 0Ch
09h 00h 05h 70h 33h 54h 4Bh 03h 53h Five characters: 70h 33h 54h 4Bh 03h
s1 (46h 61h x)
-
-
-
-
Set Track 1 Suffix Code
1 Suffix can be set as 1-6 characters
2 If first character = 00h, suffix code of track 1 will not be send. It means this function is disabling.
Table 5-16. Set Track 1 Suffix Code
Command Form (Hex)
Track 1 Suffix Code