USR-DR504-E User Manual
Jinan USR IOT Technology Limited
Tech Support: h.usriot.com
46
OFF: unconnected.
33. AT+SOCKATO
Function: Query/Setting reconnect time of Socket A once timeout.
Format:
Query current Parameter:
AT+SOCKATO{CR} or AT+SOCKATO?{CR}
{CR}{LF}+SOCKATO:time{CR}{LF}{CR}{LF}
Parameters:
time: reconnect time, time range is 1~100 s. Default time is 5s.
E. g: AT+SOCKATO=10
34. AT+SOCKBTO
Function: Query/Setting reconnect time of Socket B once timeout.
Format:
Query current parameter:
AT+SOCKBTO{CR} or AT+SOCKBTO?{CR}
{CR}{LF}+SOCKBTO:time{CR}{LF}{CR}{LF}
Parameters:
time: reconnect time, time range is 1~100 s. Default time is 5s.
35. AT+SOCKRSTIM
Function: Query/Setting the maximum number of re-connections after connection failure, the device will restart
after the maximum number of re-connections.
Format:
Query current Parameter:
AT+SOCKRSTIM{CR} or AT+ SOCKRSTIM?{CR}
{CR}{LF}+ SOCKRSTIM:num{CR}{LF}{CR}{LF}
Parameter:
num: Maximum re-connection times, Setting range is 10~600 times, the default is 60 times.
36. AT+MODBUSEN
Function: Query/Setting Whether to enable Modbus protocol transformation Function.
Format:
Query current Parameter:
AT+MODBUSEN{CR} or AT+MODBUSEN?{CR}
{CR}{LF}+MODBUSEN:status{CR}{LF}{CR}{LF}
Setting: