P R O G R A M M I N G

PROGRAM MODE Continued

c

c o u n t

PGM

u

U P

d n

A-B:  Inputs on the A
channel increment the
total, while inputs on the
B channel decrement

Directional:  When input
B is inactive, input A
increments.  When input
B is active, input A
decrements

Quadrature:  The unit
accepts a phased input
from an encoder.  The
total increments when the
A channel leads the B
channel

Count Mode

Function:  Defines how the input pulses will be applied to the count value

Adjustment Range:

A+B:  Inputs on both the
A & B channels
increment the total

d i r

A

Q u A d

A +

b

b

Default Value:  A+B

Count Direction

Function:  Determines if the count value will increment from zero and change the state of the output at the
preset (Up) or decrement from the preset and change the state of the output at zero (Down)

Adjustment Range:

u P _ A r

d n _ A r

Up:  The unit will count
up from zero and activate
the output(s) when the
preset(s) is reached

Up with Auto Reset:  The
unit will count up from
zero and activate the
output(s) when the preset
is reached, then
automatically reset the
count value to zero and
continue operating

Down with Auto Reset:
The unit will begin at the
preset and incremental
pulses will cause the unit
to count down.  The
preset output will be
activated when the count
value reaches zero.  The
unit will automatically
reset its count value and
continue operating

u P

d n

Down:  Upon reset, the
unit will begin at the
preset and count down.
The preset output will
be activated when the
count value reaches
zero

Default Value:  Up

PGM

Input Type

Function:  Programs the unit to match the electrical characteristics of the input signal

Adjustment Range:

i

1 n P u t

Sinking:  The unit will
accept a NPN or dry
contact input which sinks
voltage to common

S i n

S r c

Source:  The unit will
accept an PNP input
which sources voltage

PGM

Default Value: Sinking

Summary of Contents for Series C628

Page 1: ...day to day operation and allows editing of presetvalues TheProgramModeenablestheconfigurationofvariousparametersprior toinitialoperation Theseparametersincludethoseforbasicconfigurationaswellas others...

Page 2: ...wn to the left and push it forward until it is firmly in contact with the rear face of the mounting panel and the tabs on the bracket arm are seated in the mounting grooves on the side of the unit The...

Page 3: ...inals 10 11 12 15 are not used units The neutral side for AC powered units and the negative side for DCpoweredunitsareconnectedtoTerminal 14 Transistor Outputs Your unit comes standard with 2 NPN outp...

Page 4: ...the preset in countdownoperation Parametermustbedisplayed to be reset This button can be disabled via the Front PanelResetEnable parameterinProgramMode InProgramMode No function In All modes Will abo...

Page 5: ...ccur from the least significant to the most significantdigit Use the Down Key to decrement the digituntilthedesiredvalueappears The display will wrap around from 0 to 9 Afterthedesireddigitshavebeen c...

Page 6: ...s the scroll key to enterEditOperation MSDflashing Use the scroll and edit buttons to change the valueasinOperationMode describedon page 5 Press the Program Key to enter any changes Successivepresseso...

Page 7: ...ge u P _ A r d n _ A r Up The unit will count up from zero and activate theoutput s whenthe preset s isreached Up with Auto Reset The unit will count up from zeroandactivatethe output s whenthepreset...

Page 8: ...ronicinputs andencoders DefaultValue 10000 PGM 1 Output 1 Time Function Sets the amount of time output 1 will be active once Preset 1 is reached AdjustmentRange 00 00 Latched to99 99 DefaultValue 1 00...

Page 9: ...t Range 1 to 99 Default Value 1 A d d r PGM b b A u d Baud Rate Appears only if communication board is installed and activated Function Selectstheserialcommunicationspeed AdjustmentRange 1 2 0 0 2 4 0...

Page 10: ...Determineswhetherthemulti characterparameternamewillappearonthemaindisplayfor3 secondspriortotheparametervalueappearing AdjustmentRange H E L P h Help Yes Multi characterparameter descriptionswillapp...

Page 11: ...1993 Communication Type Serial asynchronous UART to UART Data Format Open ASCII One start bit even parity seven data bits one stop bit Physical Layer RS 485 Maximum Zones 99 Baud Rate Selectable from...

Page 12: ...hich theCompanyconsentstohavereturnedshallbeshippedF O B the Company s factory TheCompanycannotassumeresponsibilityor acceptinvoicesforunauthorizedrepairstoitscomponents eventhough defective The life...

Reviews: