background image

25 

 

ASI Output: 

The Encoder does not support all the camera resolutions. If you set a resolution not supported by the 
encoder, the encoder will stop. 
The following formats are supported: 
1080i59.94 
1080i50 
1080p24 
1080p23.98 
720p59.94 
720p50 
 

Defective Pixel Correction (DPC): 

To enable the DPC properly, the following steps have to be executed: 

o

 

Switch manually to a 1080p resolution (1080p25 recommended). 

o

 

Put the lens cap on the objective lens. 

o

 

Execute: $DEFECT=0100# 

o

 

The positions of the defective pixels are saved in the FRAM and are available in all 
1080p/i and 720p resolutions, even after camera reboot. 

o

 

The Defective Pixel Correction is automatically switched on ($DPC___=0001#). 

o

 

If the return value of the DEFECT command is FFFF, choose a greater value (i.e. 
$DEFECT=0180#). 

o

 

The value used by the DEFECT command is the threshold where pixels are marked 
as defective. 

 

RAW data output: 

The camera features a RAW data output with the following specifications: 

o

 

All in the camera supported 1080p and 720p standards are able to output RAW data. 

o

 

The leftmost pixel in the first line of the active video field is a red pixel. 

o

 

For one RAW data pixel value the 4:2:2 Y and Cb values are used (Y and Cr 
accordingly). 

o

 

Use the following equation to calculate the RAW data value for one pixel (Cr 
accordingly): 

 

value = (Y-64)*8+(Cb-512) 

 

Inter camera communication (ICC): 

Using the inter camera communication (ICC) always requires two cameras connected via a special 
communication cable. The first camera has to be configured as Master the second camera has to be 
configured as Slave. 
To set up a Master/Slave configuration follow these steps: 

o

 

Set both cameras in normal mode ($sync__=0000#) 

o

 

Connect the cameras using the inter camera connection cable 

o

 

Switch camera 1 to master mode ($sync__=0001#) 

o

 

Switch camera 2 to slave mode ($sync__=0002#) 

o

 

The cameras are now in sync. 

o

 

Switch camera 2 to normal mode ($sync__=0000#) 

o

 

Switch camera 1 to normal mode ($sync__=0000#) 

o

 

Power down the camera system 

If the slave camera loose the connection to the master camera, the slave camera will immediately stop 
operation. The system will resume operation after reconnecting the master and the slave camera 
using the communication cable. To reset a slave camera when no master camera is available or 
connected, restart the slave camera and wait 10 seconds after the status LED turns blue. The camera 
will reset the internal settings memory. After a reboot the camera will start with default settings (normal 
mode). 

Summary of Contents for CUNIMA MCU [2]

Page 1: ...or even for stereoscopic 3D productions The compact design looks quite similar to CUNIMA MCU 1 and it has almost the same dimensions but the motor that drives the body is completely new new sensor ne...

Page 2: ...amera Communication ICC 10 3 7 Cleaning of the camera 10 4 Operation 11 4 1 Analog Gain 11 4 2 Edge enhancement 11 4 3 Fixed Pattern Noise Correction 11 4 4 Gamma correction 12 4 5 Shutter Speed Expos...

Page 3: ...rtner for sports entertainment show reality you name it The CUNIMA s modular accessory concept permits a continuous and flexible adaptation of the camera to the respective production requirements In t...

Page 4: ...LUT s White Balance Manual adjustment user definable presets Black Balance Manual adjustment user definable presets Saturation Manual adjustment user definable presets Gain user definable gain up to...

Page 5: ...et is complete before going on production If one of these items gets lost feel free to order it at WIGE MEDIA AG Contents 1x CUNIMA MCU 2 HD camera 1x Power Supply CUNIMA MCU 2 1x Device Cable for Pow...

Page 6: ...supply should lighten up 3 Connect the camera to the power supply by using the adaptor Fisher to XLR 7 pole 4 The captured image should appear at the BNC connector of the camera within seconds and ca...

Page 7: ...ngineered for that indented purpose CUNIMA 2 3 inch single CMOS sensor 3 2 2 C Mount thread 1 Please remove the rubber protection of the Cunima MCU 2 You can see the C Mount thread now Please note tha...

Page 8: ...side of the head of the CUNIMA can be used to fix it Make sure to align the gearwheel of the motor with the gearwheel of the lens properly 2 Connect one male 7Pin plug of the Y patch cable to the CUNI...

Page 9: ...5 2 CONNECTION DIAGRAM 3 5 3 OPERATION You can use the RCP to control the iris focus motor Navigate to IRIS in the RCP Menu and spin the MASTER Encoder see chapter 5 on the right to open or close the...

Page 10: ...ODE MASTER 3 Set the other Camera to SYNCMODE SLAVE Now both cameras should be synced If anything went wrong please restart the cameras by pulling the powerplug out of the camera Every camera restarts...

Page 11: ...ancement will adjust it to our viewing habits by making the image sharper For this purpose the edge enhancement algorithm is implemented The digital edge filter finds all the horizontal and vertical e...

Page 12: ...poor presentation of black 4 5 SHUTTER SPEED EXPOSURE TIME The Cunima MCU 2 camera with its CMOS image sensor scans the image linear Hence it is the electronic pendant to a rolling shutter Through the...

Page 13: ...tely uncompressed video signal which is especially useful for special effects keying and compositing and for inserts in film material With the RAW format an additional stop contrast range is added to...

Page 14: ...the RCP4 is limited to two cameras In the following the RCP4 which is developed for mobile occasions is explained 5 1 INTRODUCTION Controls up to 2 CUNIMA MCU 2 cameras 5 2 INSTALLATION With every RC...

Page 15: ...black level of RED 8 Controller for black level of GREEN 9 Controller for black level of BLUE The Operation of the Panel is separated in options which navigate through the menu and in direct controll...

Page 16: ...ts the black values in red green and blue from 255 to 255 0 is the standard value With the selector control 3 you can control the master black from 08 255 Analog Gain Sets an analog gain Range is 0dB...

Page 17: ...9 97 PAL 4 3 PAL 16 9 NTSC 4 3 NTSC 16 9 Detail Focus Detail is a detailing algorithm that gives you more sharpness in the image Range 0 50 Recommendation for broadcast 12 The focus value gives you in...

Page 18: ...that s selected to sync the camera Analog is an analog Black Burst BB Digital defines a Tri Level Sync Fixed Pattern Noise CMOS imager always have some fixed pattern noise that needs to be corrected T...

Page 19: ...19 Set Output Values SDI Iris Values 000 099 000 iris is completely closed 099 iris is completely opened Focus will be included in future versions...

Page 20: ...a six character command token e g SETRES for set resolution Next character is a to keep command and data 20separated Next four characters are data Please fill unused characters with 0 The frame ends w...

Page 21: ...CT Defective Pixel Correction Config 00FF reasonable values 0100 DPC___ Defective Pixel Correction on off 0000 off 0001 on 0001 DETAIL Adjust detail filter 0000 off 0001 0032 filter degree 0018 FPAUTO...

Page 22: ...nc 0002 reserved SETRES Sets a new resolution 0001 000F 0001 720p60 0002 720p50 0003 720p59 94 0004 1080i60 0005 1080i50 0006 1080i59 94 0007 1080p30 0008 1080p25 0009 1080p24 000A 1080p24 1 001 000B...

Page 23: ...1480h 1 281 WBRED_ White Balance Red 0000 27FF Bit15 0 Bit14 12 integer part Bit11 0 fractional part Default 1440h 1 266 WBGRN_ White Balance Green 0000 27FF Bit15 0 Bit14 12 integer part Bit11 0 fra...

Page 24: ...proper value After the CAMACK the correction is done and the lens cover can be removed When using the FPN command it could be necessary to readjust the blacklevel The FPAUTO command must be executed...

Page 25: ...ta pixel value the 4 2 2 Y and Cb values are used Y and Cr accordingly o Use the following equation to calculate the RAW data value for one pixel Cr accordingly value Y 64 8 Cb 512 Inter camera commun...

Page 26: ...26 _wige MEDIA AG Am Coloneum 2 D 50829 Cologne GERMANY Phone 49 221 7 88 77 626 Fax 49 221 7 88 77 429 Email cunima at wige de Website www wige de December 2011...

Reviews: