XT2500 Product Manual
Page 15 | 92
CONFIDENTIAL AND PROPRIETARY
4.9. I
NPUT
D
EFAULT
P
OLARITY
(
IDP
)
l
idp[0] -> PUD on user input 1
l
idp[1] -> PUD on user input 2
l
idp[2] -> PUD on user input 3
l
idp[3] -> PUD on user input 4
Configuration instances: 4
Command Type
Syntax
SET
Command
:wycfg idp[x] <pullup_disable>
Response
:OK
READ
Command
:rycfg idp[x]
Response
| idp[x]: polrty:<pullup_disable> (hex_val)
:OK
Parameter
Range
Description
Input active
level
0 to 1
Sets the corresponding user input "active" level by engaging an external
pullup ('0') or pulldown ('1') on corresponding that user input.
An idp setting of '1' means the user input is configured active high, so the
user input is pulled down when not driven by external influences.
An idp setting of '0' means the user input is configured active low, so the user
input is pulled up when not driven by external influences.