LED Notifications for Chime
Parameter 9: Enable or disable visual alarm for Chime mode. The LED will blink when triggered.
Values: 0
–
LED disabled (default); 1
–
LED enabled.
Size: 1 byte dec.
Indicator Command Class
You may use the indicator command class to assign tones played by your Smart Chime
–
this will also
enable you to switch between the Siren and Chime modes. Please refer to the table below for details.
Command
Tone from library
Volume and duration
INDICATOR_SET = 0x01
1
Defined in Parameters 3 and 4
INDICATOR_SET = 0x02
2
Defined in Parameters 3 and 4
INDICATOR_SET = 0x03
3
Defined in Parameters 3 and 4
INDICATOR_SET = 0x04
4
Defined in Parameters 3 and 4
INDICATOR_SET = 0x05
5
Defined in Parameters 3 and 4
INDICATOR_SET = 0x06
6
Defined in Parameters 3 and 4
INDICATOR_SET = 0x07
7
Defined in Parameters 3 and 4
INDICATOR_SET = 0x08
8
Defined in Parameters 3 and 4
INDICATOR_SET = 0x09
9
Defined in Parameters 3 and 4
INDICATOR_SET = 0x10
10
Defined in Parameters 3 and 4
ASSOCIATION
Depending on your Z-Wave gateway's home automation software capabilities, you may be able to
associate your Smart Chime in groups with other Z-Wave devices to schedule scenes and create events.
This Smart Chime supports the following association groups with up to five devices per group:
Group 1 for lifeline communication of siren / chime triggers to Z-Wave controller. Supported command
classes:
SWITCH_BINARY_REPORT
NOTIFICATION_REPORT
BATTERY_REPORT
DEVICE_RESET_LOCALLY_NOTIFICATION
Group 2 for status notifications to Z-Wave devices associated in this group. Supported command
classes:
SWITCH_BINARY_REPORT
Group 3 for notifications to Z-Wave devices associated in this group. Supported command classes:
NOTIFICATION_REPORT
NOTE: Remember to wake the device up when making any advanced changes. Just press and release the Z-
Wave button three times.
If you enter value outside of given parameter’s range, you will need to
send a
command to configure node before trying to enter a new (correct) value. Otherwise, the device will remain
unresponsive to further changes.